Please use this identifier to cite or link to this item:
https://scholarbank.nus.edu.sg/handle/10635/133776
Title: | Two years of intrauterine contraception with levonorgestrel and with copper: A randomized comparison of the TCu 380Ag and levonorgestrel 20 mcg/day device | Authors: | Sivin, I. Stern, J. Diaz, J. Diaz, M.M. Faundes, A. El Mahgoub, S. Diaz, S. Pavez, M. Coutinho, E. Mattos, C.E.R. McCarthy, T. Mishell Jr., D.R. Shoupe, D. Alvarez, F. Brache, V. Jimenez, E. |
Issue Date: | Mar-1987 | Citation: | Sivin, I., Stern, J., Diaz, J., Diaz, M.M., Faundes, A., El Mahgoub, S., Diaz, S., Pavez, M., Coutinho, E., Mattos, C.E.R., McCarthy, T., Mishell Jr., D.R., Shoupe, D., Alvarez, F., Brache, V., Jimenez, E. (1987-03). Two years of intrauterine contraception with levonorgestrel and with copper: A randomized comparison of the TCu 380Ag and levonorgestrel 20 mcg/day device. Contraception 35 (3) : 245-255. ScholarBank@NUS Repository. | Abstract: | IUDs releasing 20 mcg/day of levonorgestrel (LNg20) were in randomized trial together with the Copper T, model TCu 380Ag, in seven centers involving 2244 women. Two-year (25 months) gross cumulative pregnancy rates were 0.2 ± 0.2 and 0.9 ± 0.3 for the levonorgestrel and copper releasing devices, respectively (P > 0.05). There were no ectopic pregnancies in more than 1600 woman-years of use of each device. Removal rates for bleeding and/or pain or for medical reasons other than menstrual problems did not differ significantly between devices. Oligomenorrhea or amenorrhea prompted 10.7 per hundred (gross rate, 8.4 net rate) women using the LNg 20 IUD to request removal in the two-year period, significantly above the 0.2 per hundred rate among women with the Copper IUD (P < 0.001). At the end of two years an estimated 59.4 per 100 women were continuing use of the LNg 20 IUD, and 67.5 per 100 (P < 0.001) with the TCu 380Ag. This difference is almost wholly ascribable to a marked reduction in bleeding episodes and days among women using the LNg 20 device with concomitant removal of device. Hemoglobin rose an average of 0.5g/dl (P < 0.001) for this group whereas women using the TCu 380Ag experienced a decline of 0.2g/dl compared with baseline values (P < 0.001). © 1987. | Source Title: | Contraception | URI: | http://scholarbank.nus.edu.sg/handle/10635/133776 | ISSN: | 00107824 |
Appears in Collections: | Staff Publications |
Show full item record
Files in This Item:
There are no files associated with this item.
Google ScholarTM
Check
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.