Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/133265
Title: Median nerve compression, with tendon ruptures, after Colles' fracture
Authors: Wong, F.Y.H.
Pho, R.W.H. 
Issue Date: Jun-1984
Citation: Wong, F.Y.H., Pho, R.W.H. (1984-06). Median nerve compression, with tendon ruptures, after Colles' fracture. British Journal of Oral and Maxillofacial Surgery 9 (2) : 139-141. ScholarBank@NUS Repository.
Abstract: A rare case of rupture of the flexor pollicis longus tendon following a Colles' fracture is described. The patient also had a ruptured flexor digitorum profundus to the index finger and compression of the median nerve of the same hand. The ruptures were noted after four weeks of plaster immobilisation. Decompression of the median nerve and corrective osteotomy was performed but no tendon repair was attempted. The patient regained good function of the hand. © 1984.
Source Title: British Journal of Oral and Maxillofacial Surgery
URI: http://scholarbank.nus.edu.sg/handle/10635/133265
ISSN: 02664356
Appears in Collections:Staff Publications