Please use this identifier to cite or link to this item: https://doi.org/10.1167/iovs.03-0012
Title: Determinants of intraocular pressure and its association with glaucomatous optic neuropathy in Chinese Singaporeans: The Tanjong Pagar study
Authors: Foster, P.J.
Machin, D.
Wong, T.-Y. 
Ng, T.-P.
Kirwan, J.F.
Johnson, G.J.
Khaw, P.T.
Seah, S.K.L.
Issue Date: 1-Sep-2003
Citation: Foster, P.J., Machin, D., Wong, T.-Y., Ng, T.-P., Kirwan, J.F., Johnson, G.J., Khaw, P.T., Seah, S.K.L. (2003-09-01). Determinants of intraocular pressure and its association with glaucomatous optic neuropathy in Chinese Singaporeans: The Tanjong Pagar study. Investigative Ophthalmology and Visual Science 44 (9) : 3885-3891. ScholarBank@NUS Repository. https://doi.org/10.1167/iovs.03-0012
Abstract: PURPOSE. To examine the relationship between intraocular pressure (IOP), anthropomorphic, demographic, socioeconomic, systemic, and ocular factors and glaucomatous optic neuropathy (GON) in Chinese people. METHODS. Chinese people (n = 2000), aged 40 to 79 years, were selected from the Singapore electoral register. Of the 1717 considered eligible for examination, 1232 participated, representing a response rate of 71.8%. IOP was estimated with Goldmann applanation tonometry. The drainage angle was assessed with static and dynamic gonioscopy. The optic nerve was examined at high magnification through a dilated pupil with a fundus contact lens or a +78-D lens. Static automated visual field testing was performed on subjects with suspected glaucoma. GON was diagnosed on the basis of structural and functional abnormalities of the optic nerve. RESULTS. The main independent determinants of higher IOP were higher systolic blood pressure (P < 0.001), quadrants of any peripheral anterior synechiae (PAS, P = 0.02) and width of the drainage angle (P = 0.049). A 100-μm increase in corneal thickness was associated with an increase in mean IOP of 1.5 to 1.8 mm Hg (P < 0.001). Odds of GON increased 1.2 times per 1-mm Hg increase in screening IOP. A clear association between corneal thickness and GON was not identified. CONCLUSIONS. Clinical IOP estimates are related to systolic blood pressure and corneal thickness. Variation in IOP with angle width may suggest that trabecular compaction significantly contributes to causes of the increase in IOP, independent of angle-closure. GON is an IOP-related phenomenon among Chinese Singaporeans.
Source Title: Investigative Ophthalmology and Visual Science
URI: http://scholarbank.nus.edu.sg/handle/10635/113433
ISSN: 01460404
DOI: 10.1167/iovs.03-0012
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.