Please use this identifier to cite or link to this item:
https://doi.org/10.1167/iovs.10-6186
Title: | Comparison of candidate materials for a synthetic osteo-odonto keratoprosthesis device | Authors: | Tan, X.W. Perera, A.P.P. Tan, A. Tan, D. Khor, K.A. Beuerman, R.W. Mehta, J.S. |
Issue Date: | Jan-2011 | Citation: | Tan, X.W., Perera, A.P.P., Tan, A., Tan, D., Khor, K.A., Beuerman, R.W., Mehta, J.S. (2011-01). Comparison of candidate materials for a synthetic osteo-odonto keratoprosthesis device. Investigative Ophthalmology and Visual Science 52 (1) : 21-29. ScholarBank@NUS Repository. https://doi.org/10.1167/iovs.10-6186 | Abstract: | Purpose. Osteo-odonto keratoprosthesis is one of the most successful forms of keratoprosthesis surgery for end-stage corneal and ocular surface disease. There is a lack of detailed comparison studies on the biocompatibilities of different materials used in keratoprosthesis. The aim of this investigation was to compare synthetic bioinert materials used for keratoprosthesis surgery with hydroxyapatite (HA) as a reference. Methods. Test materials were sintered titanium oxide (TiO2), aluminum oxide (Al2O3), and yttria-stabilized zirconia (YSZ) with density >95%. Bacterial adhesion on the substrates was evaluated using scanning electron microscopy and the spread plate method. Surface properties of the implant discs were scanned using optical microscopy. Human keratocyte attachment and proliferation rates were assessed by cell counting and MTT assay at different time points. Morphologic analysis and immunoblotting were used to evaluate focal adhesion formation, whereas cell adhesion force was measured with a multi-mode atomic force microscope. Results. The authors found that bacterial adhesion on the TiO2, Al2O3, and YSZ surfaces were lower than that on HA substrates. TiO2 significantly promoted keratocyte proliferation and viability compared with HA, Al2O3 and YSZ. Immunoflu-orescent imaging analyses, immunoblotting, and atomic force microscope measurement revealed that TiO2 surfaces enhanced cell spreading and cell adhesion compared with HA and Al2O3. Conclusions. TiO2 is the most suitable replacement candidate for use as skirt material because it enhanced cell functions and reduced bacterial adhesion. This would, in turn, enhance tissue integration and reduce device failure rates during keratoprosthesis surgery. © 2011 The Association for Research in Vision and Ophthalmology, Inc. | Source Title: | Investigative Ophthalmology and Visual Science | URI: | http://scholarbank.nus.edu.sg/handle/10635/109974 | ISSN: | 01460404 | DOI: | 10.1167/iovs.10-6186 |
Appears in Collections: | Staff Publications |
Show full item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.