Please use this identifier to cite or link to this item: https://doi.org/10.1117/12.810956
Title: ARGALI- An automatic cup-to-disc ratio measurement system for Glaucoma detection and analysis framework
Authors: Liu, J.
Wong, D.W.K.
Lim, J.H.
Li, H.
Tan, N.M.
Wong, T.Y. 
Keywords: Cup-to-disc ratio
Glaucoma
Level-set
Neural network
Issue Date: 2009
Citation: Liu, J., Wong, D.W.K., Lim, J.H., Li, H., Tan, N.M., Wong, T.Y. (2009). ARGALI- An automatic cup-to-disc ratio measurement system for Glaucoma detection and analysis framework. Progress in Biomedical Optics and Imaging - Proceedings of SPIE 7260 : -. ScholarBank@NUS Repository. https://doi.org/10.1117/12.810956
Abstract: Glaucoma is an irreversible ocular disease leading to permanent blindness. However, early detection can be effective in slowing or halting the progression of the disease. Physiologically, glaucoma progression is quantified by increased excavation of the optic cup. This progression can be quantified in retinal fundus images via the optic cup to disc ratio (CDR), since in increased glaucomatous neuropathy, the relative size of the optic cup to the optic disc is increased. The ARGALI framework constitutes of various segmentation approaches employing level set, color intensity thresholds and ellipse fitting for the extraction of the optic cup and disc from retinal images as preliminary steps. Following this, different combinations of the obtained results are then utilized to calculate the corresponding CDR values. The individual results are subsequently fused using a neural network. The learning function of the neural network is trained with a set of 100 retinal images For testing, a separate set 40 images is then used to compare the obtained CDR against a clinically graded CDR, and it is shown that the neural network-based result performs better than the individual components, with 96% of the results within intra-observer variability. The results indicate good promise for the further development of ARGALI as a tool for the early detection of glaucoma ©2009 SPIE.
Source Title: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
URI: http://scholarbank.nus.edu.sg/handle/10635/109746
ISBN: 9780819475114
ISSN: 16057422
DOI: 10.1117/12.810956
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.