Please use this identifier to cite or link to this item:
https://doi.org/10.1016/j.cmpb.2013.02.004
Title: | Retinal artery-vein caliber grading using color fundus imaging | Authors: | Bhuiyan, A. Kawasaki, R. Lamoureux, E. Ramamohanarao, K. Wong, T.Y. |
Keywords: | Blood vessel Central Retinal Artery Equivalent (CRAE) Central Retinal Vein Equivalent (CRVE) Retinal image Vessel caliber |
Issue Date: | Jul-2013 | Citation: | Bhuiyan, A., Kawasaki, R., Lamoureux, E., Ramamohanarao, K., Wong, T.Y. (2013-07). Retinal artery-vein caliber grading using color fundus imaging. Computer Methods and Programs in Biomedicine 111 (1) : 104-114. ScholarBank@NUS Repository. https://doi.org/10.1016/j.cmpb.2013.02.004 | Abstract: | Recent research suggests that retinal vessel caliber (or cross-sectional width) measured from retinal photographs is an important feature for predicting cardiovascular diseases (CVDs). One of the most utilized measures is to quantify retinal arteriolar and venular caliber as the Central Retinal Artery Equivalent (CRAE) and Central Retinal Vein Equivalent (CRVE). However, current computer tools utilize manual or semi-automatic grading methods to estimate CRAE and CRVE. These methods involve a significant amount of grader's time and can add a significant level of inaccuracy due to repetitive nature of grading and intragrader distances. An automatic and time efficient grading of the vessel caliber with highly repeatable measurement is essential, but is technically challenging due to a substantial variation of the retinal blood vessels' properties. In this paper, we propose a new technique to measure the retinal vessel caliber, which is an "edge-based" vessel tracking method. We measured CRAE and CRVE from each of the vessel types. We achieve very high accuracy (average 96.23%) for each of the cross-sectional width measurement compared to manually graded width. For overall vessel caliber measurement accuracy of CRAE and CRVE, we compared the results with an existing semi-automatic method which showed high correlation of 0.85 and 0.92, respectively. The intra-grader reproducibility of our method was high, with the correlation coefficient of 0.881 for CRAE and 0.875 for CRVE. © 2013 Elsevier Ireland Ltd. | Source Title: | Computer Methods and Programs in Biomedicine | URI: | http://scholarbank.nus.edu.sg/handle/10635/109597 | ISSN: | 01692607 | DOI: | 10.1016/j.cmpb.2013.02.004 |
Appears in Collections: | Staff Publications |
Show full item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.