Please use this identifier to cite or link to this item:
https://doi.org/10.1016/j.ajo.2010.09.032
Title: | Determinants of image quality of heidelberg retina tomography II and its association with optic disc parameters in a population-based setting | Authors: | Zheng, Y. Cheung, C.Y. Wong, T.Y. Wong, W. Loon, S.-C. Aung, T. |
Issue Date: | Apr-2011 | Citation: | Zheng, Y., Cheung, C.Y., Wong, T.Y., Wong, W., Loon, S.-C., Aung, T. (2011-04). Determinants of image quality of heidelberg retina tomography II and its association with optic disc parameters in a population-based setting. American Journal of Ophthalmology 151 (4) : 663-670. ScholarBank@NUS Repository. https://doi.org/10.1016/j.ajo.2010.09.032 | Abstract: | Purpose: To assess the determinants of image quality of Heidelberg Retina Tomography II (HRT II) and its association with optic disc parameters in a population-based setting. Design Population-based, cross-sectional study involving 3280 (78.7% response) Asian Malays aged 40 to 80 years. Methods Three thousand fifty-six participants completed the HRT II test. Image quality was assessed using the mean pixel height standard deviation generated by the HRT II, with lower mean pixel height standard deviation indicating higher quality. Participants underwent an interviewer-administered questionnaire and a standardized ophthalmic examination, including visual acuity, applanation tonometry, gonioscopy, refraction, automated perimetry, and lens and fundus photography. Results The mean (standard deviation) and median of mean pixel height standard deviation in the study population were 34 (34) and 23 μm respectively. In multivariate regression models, older age and the presence of visual impairment, blindness, high myopia, and cataract were significantly associated with greater mean pixel height standard deviation (P < .05 for all). People with a higher mean pixel height standard deviation were more likely to have smaller rim area and greater cup depth. Conclusion People who are older or have high myopia, visual impairment, blindness, or cataract are more likely to have poor HRT II image quality. Poorer image quality is in turn associated with smaller optic rim area and greater cup depth. These data provide useful information when the HRT instrument is used for diagnosing glaucoma in the general population. © 2011 Elsevier Inc. All rights reserved. | Source Title: | American Journal of Ophthalmology | URI: | http://scholarbank.nus.edu.sg/handle/10635/108332 | ISSN: | 00029394 | DOI: | 10.1016/j.ajo.2010.09.032 |
Appears in Collections: | Staff Publications |
Show full item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.