Please use this identifier to cite or link to this item: https://doi.org/10.1080/02640410500189124
Title: Effects of allometric scaling and isokinetic testing methods on the relationship between countermovement jump and quadriceps torque and power
Authors: Pua, Y.-H.
Teik-Hin Koh, M.
Teo, Y.-Y. 
Keywords: Body mass
Log-linear modelling
Reciprocal testing
Velocities
Issue Date: Apr-2006
Citation: Pua, Y.-H., Teik-Hin Koh, M., Teo, Y.-Y. (2006-04). Effects of allometric scaling and isokinetic testing methods on the relationship between countermovement jump and quadriceps torque and power. Journal of Sports Sciences 24 (4) : 423-432. ScholarBank@NUS Repository. https://doi.org/10.1080/02640410500189124
Abstract: Determination of the strongest possible relationship between isokinetic quadriceps and functional performance measurements in healthy females would allow sports medicine practitioners to establish normative values when examining muscular performance in injured females. Previous attempts to correlate both measurements have, however, produced inconsistent results. The purpose of this study was to examine the effects of allometric scaling, isokinetic testing velocities, reciprocal and non-reciprocal isokinetic testing on the relationship between countermovement jump (CMJ) and isokinetic quadriceps torque and power in recreational females athletes. Seventeen females (age 21.0 ± 2.0 years, body mass index 19.5 ± 1.0 kg · m-2) performed isokinetic quadriceps and CMJ tests. Isokinetic peak torque and average power were obtained reciprocally and non-reciprocally at 1.05 and 3.14 rad · s-1, and were corrected for body mass by allometric modelling. Pearson product-moment correlation (r) was used to assess the relationship between the isokinetic parameters and the CMJ measurements. Coefficients of determination (r2) were calculated to determine the magnitude of common variance. The r-values for all non-allometrically modelled non-reciprocal parameters were greater (r = 0.58-0.63) than isokinetic parameters obtained reciprocally (r = 0.28-0.47). Using allometric scaling, non-reciprocal isokinetic data accounted for an additional 2-9% of the CMJ height variance, and statistically significant correlations were obtained at both 1.05 and 3.14 rad · s-1. Allometrically scaled, non-reciprocal isokinetic peak torque and average power at 1.05 rad · s-1 had the highest correlation with CMJ (r2= 0.49). At both 1.05 and 3.14 rad · s-1, non-reciprocal quadriceps parameters correlated more closely with CMJ measurements than do reciprocal contractions. Normalization for body size by allometrically scaling may further improve correlations with CMJ performance. © 2006 Taylor & Francis.
Source Title: Journal of Sports Sciences
URI: http://scholarbank.nus.edu.sg/handle/10635/105103
ISSN: 02640414
DOI: 10.1080/02640410500189124
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.