Please use this identifier to cite or link to this item:
https://doi.org/10.1016/j.aca.2007.05.047
DC Field | Value | |
---|---|---|
dc.title | Selective and sensitive electrochemical detection of glucose in neutral solution using platinum-lead alloy nanoparticle/carbon nanotube nanocomposites | |
dc.contributor.author | Cui, H.-F. | |
dc.contributor.author | Ye, J.-S. | |
dc.contributor.author | Zhang, W.-D. | |
dc.contributor.author | Li, C.-M. | |
dc.contributor.author | Luong, J.H.T. | |
dc.contributor.author | Sheu, F.-S. | |
dc.date.accessioned | 2014-10-16T09:40:22Z | |
dc.date.available | 2014-10-16T09:40:22Z | |
dc.date.issued | 2007-07-02 | |
dc.identifier.citation | Cui, H.-F., Ye, J.-S., Zhang, W.-D., Li, C.-M., Luong, J.H.T., Sheu, F.-S. (2007-07-02). Selective and sensitive electrochemical detection of glucose in neutral solution using platinum-lead alloy nanoparticle/carbon nanotube nanocomposites. Analytica Chimica Acta 594 (2) : 175-183. ScholarBank@NUS Repository. https://doi.org/10.1016/j.aca.2007.05.047 | |
dc.identifier.issn | 00032670 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/97878 | |
dc.description.abstract | Electrodeposition of Pt-Pb nanoparticles (PtPbNPs) to multi-walled carbon nanotubes (MWCNTs) resulted in a stable PtPbNP/MWCNT nanocomposite with high electrocatalytic activity to glucose oxidation in either neutral or alkaline medium. More importantly, the nanocomposite electrode with a slight modification exhibited high sensitivity, high selectivity, and low detection limit in amperometric glucose sensing at physiological neutral pH (poised at a negative potential). At +0.30 V in neutral solution, the nanocomposite electrode exhibited linearity up to 11 mM of glucose with a sensitivity of 17.8 μA cm-2 mM-1 and a detection limit of 1.8 μM (S/N = 3). Electroactive ascorbic acid (0.1 mM), uric acid (0.1 mM) and fructose (0.3 mM) invoked only 23%, 14% and 9%, respectively, of the current response obtained for 3 mM glucose. At -0.15 V in neutral solution, the electrode responded linearly to glucose up to 5 mM with a detection limit of 0.16 mM (S/N = 3) and detection sensitivity of ∼18 μA cm-2 mM-1. At this negative potential, ascorbic acid, uric acid, and fructose were not electroactive, therefore, not interfering with glucose sensing. Modification of the nanocomposite electrode with Nafion coating followed by electrodeposition of a second layer of PtPbNPs on the Nafion coated PtPbNP/MWCNT nanocomposite produced a glucose sensor (poised at -0.15 V) with a lower detection limit (7.0 μM at S/N = 3) and comparable sensitivity, selectivity and linearity compared to the PtPbNP/MWCNT nanocomposite. The Nafion coating lowered the detection limit by reducing the background noise, while the second layer of PtPbNPs restored the sensitivity to the level before Nafion coating. © 2007 Elsevier B.V. All rights reserved. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.aca.2007.05.047 | |
dc.source | Scopus | |
dc.subject | Amperometry | |
dc.subject | Carbon nanotube | |
dc.subject | Glucose detection | |
dc.subject | Interferences | |
dc.subject | Nafion | |
dc.subject | Platinum-lead nanoparticle | |
dc.type | Article | |
dc.contributor.department | PHYSICS | |
dc.contributor.department | BIOLOGICAL SCIENCES | |
dc.description.doi | 10.1016/j.aca.2007.05.047 | |
dc.description.sourcetitle | Analytica Chimica Acta | |
dc.description.volume | 594 | |
dc.description.issue | 2 | |
dc.description.page | 175-183 | |
dc.description.coden | ACACA | |
dc.identifier.isiut | 000248111100004 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.