Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.chroma.2004.09.083
DC FieldValue
dc.titleAnalysis of endocrine disrupting alkylphenols, chlorophenols and bisphenol-A using hollow fiber-protected liquid-phase microextraction coupled with injection port-derivatization gas chromatography-mass spectrometry
dc.contributor.authorBasheer, C.
dc.contributor.authorLee, H.K.
dc.date.accessioned2014-10-16T08:20:23Z
dc.date.available2014-10-16T08:20:23Z
dc.date.issued2004-11-19
dc.identifier.citationBasheer, C., Lee, H.K. (2004-11-19). Analysis of endocrine disrupting alkylphenols, chlorophenols and bisphenol-A using hollow fiber-protected liquid-phase microextraction coupled with injection port-derivatization gas chromatography-mass spectrometry. Journal of Chromatography A 1057 (1-2) : 163-169. ScholarBank@NUS Repository. https://doi.org/10.1016/j.chroma.2004.09.083
dc.identifier.issn00219673
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/93099
dc.description.abstractLiquid-phase microextraction (LPME) coupled with gas chromatography-mass spectrometry were used to determine alkylphenols (APs), chlorophenols (CPs) and bisphenol-A (BPA) in aqueous samples. APs, CPs and BPA are highly polar compounds and need to be derivatized before analysis by GC-MS. In this work, they were derivatized in the GC injection port with bis(trimethylsilyl) trifluoroacetamide (BSTFA). The analytes were extracted directly from 5 ml of sample solution using 5 μl of organic solvent though a porous polypropylene hollow fiber. The hollow fiber, filled with an immiscible organic solvent (ca. 5 μl), was immersed in the sample solution which was stirred during the 30-min extraction. An aliquot (2 μl) of the extract and 2 μl of BSTFA were then consecutively injected into the GC injection port. Extraction parameters such as extraction time, pH of sample, concentration of salt added, and stirring rate were optimised. The proposed LPME provided a good average enrichment factor of up to 162-fold, reproducibility ranging from 5.9 to 13.9% (n = 4), and good linearity (r 2 = 0.995) for spiked water samples. The limits of detection (LODs) ranged between 0.005 and 0.015 μg l -1 (S/N = 3) using GC-MS with selective ion monitoring and limits of quantification were in the range of 0.012-0.026 μg l -1. A comparative study was performed between LPME, headspace solid-phase microextraction (HS-SPME) and liquid-liquid extraction (LLE). The results obtained suggested that hollow fiber LPME was a rapid, simple and efficient technique for APs, CPs and BPA, and provided a good alternative to SPME and LLE. Finally, the proposed method was applied to monitor Singapore coastal water samples. © 2004 Elsevier B.V. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.chroma.2004.09.083
dc.sourceScopus
dc.subjectAlkylphenols
dc.subjectBisphenol-A
dc.subjectDerivatization
dc.subjectHollow fiber membrane
dc.subjectLiquid-phase microextraction
dc.subjectSeawater analysis
dc.typeArticle
dc.contributor.departmentCHEMISTRY
dc.description.doi10.1016/j.chroma.2004.09.083
dc.description.sourcetitleJournal of Chromatography A
dc.description.volume1057
dc.description.issue1-2
dc.description.page163-169
dc.description.codenJCRAE
dc.identifier.isiut000225143900019
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.