Please use this identifier to cite or link to this item: https://doi.org/10.1007/s10856-012-4578-6
DC FieldValue
dc.titleIn vivo evaluation of titanium oxide and hydroxyapatite as an artificial cornea skirt
dc.contributor.authorTan, X.W.
dc.contributor.authorBeuerman, R.W.
dc.contributor.authorShi, Z.L.
dc.contributor.authorNeoh, K.G.
dc.contributor.authorTan, D.
dc.contributor.authorKhor, K.A.
dc.contributor.authorMehta, J.S.
dc.date.accessioned2014-10-09T06:51:17Z
dc.date.available2014-10-09T06:51:17Z
dc.date.issued2012-04
dc.identifier.citationTan, X.W., Beuerman, R.W., Shi, Z.L., Neoh, K.G., Tan, D., Khor, K.A., Mehta, J.S. (2012-04). In vivo evaluation of titanium oxide and hydroxyapatite as an artificial cornea skirt. Journal of Materials Science: Materials in Medicine 23 (4) : 1063-1072. ScholarBank@NUS Repository. https://doi.org/10.1007/s10856-012-4578-6
dc.identifier.issn09574530
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/89219
dc.description.abstractKeratoprosthetic devices are subject to chronic inflammatory, pathological processes and the external environment that affect their stability and biocompatibility with the ocular surface and adjacent ocular tissues. We compared the corrosion resistance property and tissue-implant reaction of titaniumoxide (TiO2)with hydroxyapatite (HA) in artificial tear fluid and a rabbit skin implantation model. The dissolution properties of the implant surfaces were evaluated with scanning electronic microscope (SEM) and atomic force microscope (AFM). Tissue inflammatory reactions were evaluated by Hematoxylin & Eosin staining, avidin biotin peroxidase complex (ABC) immunoassay and immunofluorescence. SEM and AFM images showed that there was less pitting corrosion on the surface of TiO2 implants compared with HA. TiO2 and HA exhibited a similar pattern of foreign body capsule formation and inflammatory cellular responses. The Collagen I/Collagen III ratio of the TiO2 capsule was higher than that of the HA capsule. TiO 2 implants possess a high corrosion resistance property both in vitro and in vivo and the inflammatory cellular response to TiO2 is similar to HA. With regards to corrosion resistance and inflammatory tissue responses, TiO2 appears to be a promising material for keratoprosthetic skirt devices. © Springer Science+Business Media, LLC 2012.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1007/s10856-012-4578-6
dc.sourceScopus
dc.typeArticle
dc.contributor.departmentCHEMICAL & BIOMOLECULAR ENGINEERING
dc.contributor.departmentDUKE-NUS GRADUATE MEDICAL SCHOOL S'PORE
dc.description.doi10.1007/s10856-012-4578-6
dc.description.sourcetitleJournal of Materials Science: Materials in Medicine
dc.description.volume23
dc.description.issue4
dc.description.page1063-1072
dc.description.codenJSMME
dc.identifier.isiut000302345400021
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.