dc.titleDetermination of charge transfer resistance and capacitance of microbial fuel cell through a transient response analysis of cell voltage
dc.contributor.authorHa, P.T.
dc.contributor.authorMoon, H.
dc.contributor.authorKim, B.H.
dc.contributor.authorNg, H.Y.
dc.contributor.authorChang, I.S.
dc.date.accessioned2014-10-08T08:32:02Z
dc.date.available2014-10-08T08:32:02Z
dc.date.issued2010-03-15
dc.identifier.citationHa, P.T., Moon, H., Kim, B.H., Ng, H.Y., Chang, I.S. (2010-03-15). Determination of charge transfer resistance and capacitance of microbial fuel cell through a transient response analysis of cell voltage. Biosensors and Bioelectronics 25 (7) : 1629-1634. ScholarBank@NUS Repository. https://doi.org/10.1016/j.bios.2009.11.023
dc.identifier.issn09565663
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/87480
dc.description.abstractAn alternative method for determining the charge transfer resistance and double-layer capacitance of microbial fuel cells (MFCs), easily implemented without a potentiostat, was developed. A dynamic model with two parameters, the charge transfer resistance and double-layer capacitance of electrodes, was derived from a linear differential equation to depict the current generation with respect to activation overvoltage. This model was then used to fit the transient cell voltage response to the current step change during the continuous operation of a flat-plate typeMFCfed with acetate. Variations of the charge transfer resistance and the capacitance value with respect to the MFC design conditions (biocatalyst existence and electrode area) and operating parameters (acetate concentration and buffer strength in the catholyte) were then determined to elucidate the validity of the proposed method. This model was able to describe the dynamic behavior of the MFC during current change in the activation loss region; having an R2 value of over 0.99 in most tests. Variations of the charge transfer resistance value (thousands of Ω) according to the change of the design factors and operational factors were well-correlated with the correspondingMFC performances. However, though the capacitance values (~0.02 F) reflected the expected trend according to the electrode area change and catalyst property, they did not show significant variation with changes in either the acetate concentration or buffer strength. © 2009 Elsevier B.V.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.bios.2009.11.023
dc.sourceScopus
dc.subjectCharge transfer resistance
dc.subjectDouble-layer capacitance
dc.subjectMicrobial fuel cell
dc.subjectTransient response analysis
dc.typeArticle
dc.contributor.departmentDIVISION OF ENVIRONMENTAL SCIENCE & ENGG
dc.description.doi10.1016/j.bios.2009.11.023
dc.description.sourcetitleBiosensors and Bioelectronics
dc.description.volume25
dc.description.issue7
dc.description.page1629-1634
dc.description.codenBBIOE
dc.identifier.isiut000275978700012
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

55
checked on Aug 19, 2019

WEB OF SCIENCETM
Citations

53
checked on Aug 19, 2019

Page view(s)

33
checked on Aug 17, 2019

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.