Title: | Determination of charge transfer resistance and capacitance of microbial fuel cell through a transient response analysis of cell voltage | Authors: | Ha, P.T. Moon, H. Kim, B.H. Ng, H.Y. Chang, I.S. |
Keywords: | Charge transfer resistance Double-layer capacitance Microbial fuel cell Transient response analysis |
Issue Date: | 15-Mar-2010 | Citation: | Ha, P.T., Moon, H., Kim, B.H., Ng, H.Y., Chang, I.S. (2010-03-15). Determination of charge transfer resistance and capacitance of microbial fuel cell through a transient response analysis of cell voltage. Biosensors and Bioelectronics 25 (7) : 1629-1634. ScholarBank@NUS Repository. https://doi.org/10.1016/j.bios.2009.11.023 | Abstract: | An alternative method for determining the charge transfer resistance and double-layer capacitance of microbial fuel cells (MFCs), easily implemented without a potentiostat, was developed. A dynamic model with two parameters, the charge transfer resistance and double-layer capacitance of electrodes, was derived from a linear differential equation to depict the current generation with respect to activation overvoltage. This model was then used to fit the transient cell voltage response to the current step change during the continuous operation of a flat-plate typeMFCfed with acetate. Variations of the charge transfer resistance and the capacitance value with respect to the MFC design conditions (biocatalyst existence and electrode area) and operating parameters (acetate concentration and buffer strength in the catholyte) were then determined to elucidate the validity of the proposed method. This model was able to describe the dynamic behavior of the MFC during current change in the activation loss region; having an R2 value of over 0.99 in most tests. Variations of the charge transfer resistance value (thousands of Ω) according to the change of the design factors and operational factors were well-correlated with the correspondingMFC performances. However, though the capacitance values (~0.02 F) reflected the expected trend according to the electrode area change and catalyst property, they did not show significant variation with changes in either the acetate concentration or buffer strength. © 2009 Elsevier B.V. | Source Title: | Biosensors and Bioelectronics | URI: | http://scholarbank.nus.edu.sg/handle/10635/87480 | ISSN: | 09565663 | DOI: | 10.1016/j.bios.2009.11.023 |
Appears in Collections: | Staff Publications |
Show full item record
Files in This Item:
There are no files associated with this item.
SCOPUSTM
Citations
66
checked on Mar 4, 2021
WEB OF SCIENCETM
Citations
60
checked on Mar 4, 2021
Page view(s)
64
checked on Feb 28, 2021
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.