Please use this identifier to cite or link to this item: https://doi.org/10.1023/B:WATE.0000038899.30233.a9
DC FieldValue
dc.titleA novel high capacity biofilm reactor system for treatment of domestic sewage
dc.contributor.authorOng, S.L.
dc.contributor.authorLiu, Y.
dc.contributor.authorLee, L.Y.
dc.contributor.authorHu, J.Y.
dc.contributor.authorNg, W.J.
dc.date.accessioned2014-10-07T06:25:56Z
dc.date.available2014-10-07T06:25:56Z
dc.date.issued2004-09
dc.identifier.citationOng, S.L., Liu, Y., Lee, L.Y., Hu, J.Y., Ng, W.J. (2004-09). A novel high capacity biofilm reactor system for treatment of domestic sewage. Water, Air, and Soil Pollution 157 (1-4) : 245-256. ScholarBank@NUS Repository. https://doi.org/10.1023/B:WATE.0000038899.30233.a9
dc.identifier.issn00496979
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/84505
dc.description.abstractA lab-scale novel biofilm reactor system, Ultra-Compact Biofilm Reactor (UCBR), was studied to investigate its performance and operational characteristics for domestic sewage treatment. The reactor was operated at four different hydraulic retention times, namely, 90, 60, 30 and 15 min. The operating ranges of volumetric loading rates in terms of COD, BOD 5, NH + 4-N and TKN were 5.6-62.1 kg COD/m 3 d, 2.6-32.5 BOD 5/m 3 d, 0.6-3.2 kg NH + 4-N/m 3 d and 0.82-6.2 kg TKN/m 3 d, respectively. The COD, BOD 5 and NH + 4-N removal efficiencies at 90-min hydraulic retention time (HRT) and 60-min HRT could exceed 80%, 90% and 99%, respectively. The corresponding maximum biomass concentrations were 12.0 g/L and 15.0 g/L at 90-min HRT and 60-min HRT, respectively. At 30-min HRT, the biomass concentration increased to a maximum of 24.0 g/L. However, COD and BOD 5 removal efficiencies decreased to 75% and 80%, respectively, while the NH + 4-N nitrification efficiency decreased to only 25% to 30%. These observations suggested that high biomass concentration alone was not sufficient to provide a high removal capacity in a UCBR. Further reduction in HRT to 15 min led to an excessive biomass decline from 22.5 g/L to 4.0 g/L. On the whole, the UCBR was able to sustain COD removal and NH + 4-N conversion of up to 5.96-18.70 kg COD/m 3 d and 0.73-1.00 kg NH + 4-N/m 3 d, respectively.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1023/B:WATE.0000038899.30233.a9
dc.sourceScopus
dc.subjectcarbon removal
dc.subjectdomestic sewage
dc.subjecthydraulic retention time
dc.subjectNH + 4-N conversion
dc.subjectultra-compact biofilm reactor
dc.typeArticle
dc.contributor.departmentCIVIL ENGINEERING
dc.description.doi10.1023/B:WATE.0000038899.30233.a9
dc.description.sourcetitleWater, Air, and Soil Pollution
dc.description.volume157
dc.description.issue1-4
dc.description.page245-256
dc.description.codenWAPLA
dc.identifier.isiut000223486100017
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.