Please use this identifier to cite or link to this item:
https://doi.org/10.1063/1.3457353
DC Field | Value | |
---|---|---|
dc.title | Magnetoresistive effect in graphene nanoribbon due to magnetic field induced band gap modulation | |
dc.contributor.author | Kumar, S.B. | |
dc.contributor.author | Jalil, M.B.A. | |
dc.contributor.author | Tan, S.G. | |
dc.contributor.author | Liang, G. | |
dc.date.accessioned | 2014-10-07T04:32:02Z | |
dc.date.available | 2014-10-07T04:32:02Z | |
dc.date.issued | 2010-08-01 | |
dc.identifier.citation | Kumar, S.B., Jalil, M.B.A., Tan, S.G., Liang, G. (2010-08-01). Magnetoresistive effect in graphene nanoribbon due to magnetic field induced band gap modulation. Journal of Applied Physics 108 (3) : -. ScholarBank@NUS Repository. https://doi.org/10.1063/1.3457353 | |
dc.identifier.issn | 00218979 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/82664 | |
dc.description.abstract | The electronic properties of armchair graphene nanoribbons (AGNRs) can be significantly modified from semiconducting to metallic states by applying a uniform perpendicular magnetic field (B-field). Here, we theoretically study the band gap modulation induced by a perpendicular B-field. The applied B-field causes the lowest conduction subband and the topmost valence subband to move closer to one another to form the n=0 Landau level. We exploit this effect to realize a device relevant magnetoresistive (MR) modulation. Unlike in conventional spin-valves, this intrinsic MR effect is realized without the use of any ferromagnetic leads. The AGNRs with number of dimers, Na=3p+1 [p=1,2,3,...] show the most promising behavior for MR applications with large conductance modulation, and hence, high MR ratio at the optimal source-drain bias. However, the MR is suppressed at higher temperature due to the spread of the Fermi function distribution. We also investigate the importance of the source-drain bias in optimizing the MR. Lastly, we show that edge roughness of AGNRs has the unexpected effect of improving the magnetic sensitivity of the device and thus increasing the MR ratio. © 2010 American Institute of Physics. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1063/1.3457353 | |
dc.source | Scopus | |
dc.type | Article | |
dc.contributor.department | ELECTRICAL & COMPUTER ENGINEERING | |
dc.description.doi | 10.1063/1.3457353 | |
dc.description.sourcetitle | Journal of Applied Physics | |
dc.description.volume | 108 | |
dc.description.issue | 3 | |
dc.description.page | - | |
dc.description.coden | JAPIA | |
dc.identifier.isiut | 000280941000053 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
SCOPUSTM
Citations
28
checked on May 13, 2022
WEB OF SCIENCETM
Citations
23
checked on May 13, 2022
Page view(s)
175
checked on May 12, 2022
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.