Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.mbs.2010.11.004
DC FieldValue
dc.titleHysteresis modeling for calcium-mediated ciliary beat frequency in airway epithelial cells
dc.contributor.authorQin, K.-R.
dc.contributor.authorXiang, C.
dc.date.accessioned2014-10-07T04:29:58Z
dc.date.available2014-10-07T04:29:58Z
dc.date.issued2011-01
dc.identifier.citationQin, K.-R., Xiang, C. (2011-01). Hysteresis modeling for calcium-mediated ciliary beat frequency in airway epithelial cells. Mathematical Biosciences 229 (1) : 101-108. ScholarBank@NUS Repository. https://doi.org/10.1016/j.mbs.2010.11.004
dc.identifier.issn00255564
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/82487
dc.description.abstractA hysteresis model is proposed to describe calcium-mediated Ciliary beat frequency (CBF) in airway epithelial cells. In this dynamic model, the kinetics of coupling between calcium and CBF is posited as a two-step configuration. First, Ca2+ directly binds to or indirectly acts on the axonemal proteins to modulate the activity of axonemal proteins. This step can be modeled by a Hill function in biochemistry. In the second step, the activity of axonemal proteins interacts with the sliding velocity of axonemal microtubules, the equivalent to regulating the CBF. The well-known Bouc-Wen model for hysteresis in mechanical engineering, which can only generate the stable clockwise hysteresis loops, is modified to describe the counter clockwise hysteresis loops commonly observed in the biological experiments. Based upon this new hysteresis model, the dynamic behavior of calcium-regulated CBF in epithelial airway cells is investigated through simulation studies. The numerical results demonstrate that the CBF dynamics in airway epithelial cells predicted by the hysteresis model is more consistent with the experimental observations than that predicted by previous static model in the literature. © 2010 Elsevier Inc.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.mbs.2010.11.004
dc.sourceScopus
dc.subjectAirway epithelial cells
dc.subjectCalcium
dc.subjectCiliary beat frequency (CBF)
dc.subjectDynamic model
dc.subjectHysteresis
dc.subjectStatic model
dc.typeArticle
dc.contributor.departmentELECTRICAL & COMPUTER ENGINEERING
dc.description.doi10.1016/j.mbs.2010.11.004
dc.description.sourcetitleMathematical Biosciences
dc.description.volume229
dc.description.issue1
dc.description.page101-108
dc.description.codenMABIA
dc.identifier.isiut000286859100010
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.