dc.titleDSP-based automated error-reducing flux-linkage-measurement method for switched reluctance motors
dc.contributor.authorCheok, A.D.
dc.contributor.authorWang, Z.
dc.date.accessioned2014-10-07T04:26:19Z
dc.date.available2014-10-07T04:26:19Z
dc.date.issued2007-12
dc.identifier.citationCheok, A.D., Wang, Z. (2007-12). DSP-based automated error-reducing flux-linkage-measurement method for switched reluctance motors. IEEE Transactions on Instrumentation and Measurement 56 (6) : 2245-2253. ScholarBank@NUS Repository. https://doi.org/10.1109/TIM.2007.904562
dc.identifier.issn00189456
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/82179
dc.description.abstractThe switched reluctance motor (SRM) has received considerable attention from researchers for its many inherent advantages, and thus, it has become a popular research topic in the field of variable-speed drives as well as servo drives. Research on SRMs mainly includes their design, modeling and performance analysis, control, as well as applications. However, for verification of design, performance prediction, as well as development of a high-performance sensorless control algorithm, accurate measurement of the magnetic characteristics of the SRM is most critical. Hence, one of the most important problems in the field of SRMs is a practical and accurate instrumentation system for the measurement of the SRM magnetic characteristics. This paper first describes an accurate and fully automated digital method for the measurement of the magnetic characteristic of SRMs, which includes online offset-error removal and winding resistance estimation. In this method, a digital-signal-processor-based virtual instrumentation for measurement of flux linkage is developed. Then, the results of the measurement conducted on a four-phase SRM are presented. The accuracy of the measurement system is verified by comparing with that found via a magnetic analyzer. Finally, the various sources of errors and their contributions to the errors are discussed. The scheme can also be used, in general, for transformers or inductors. © 2007 IEEE.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/TIM.2007.904562
dc.sourceScopus
dc.subjectAutomatic test equipment
dc.subjectError analysis
dc.subjectMagnetic field measurement
dc.subjectMagnetic fields
dc.subjectMeasurement
dc.subjectReluctance motors
dc.subjectTesting
dc.typeArticle
dc.contributor.departmentELECTRICAL & COMPUTER ENGINEERING
dc.description.doi10.1109/TIM.2007.904562
dc.description.sourcetitleIEEE Transactions on Instrumentation and Measurement
dc.description.volume56
dc.description.issue6
dc.description.page2245-2253
dc.description.codenIEIMA
dc.identifier.isiut000251745500019
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.