dc.titleImproved implementation of four-standard procedure for calibrating six-port reflectometers
dc.contributor.authorQiao, L.
dc.contributor.authorYeo, S.P.
dc.date.accessioned2014-10-07T02:59:01Z
dc.date.available2014-10-07T02:59:01Z
dc.date.issued1995-06
dc.identifier.citationQiao, L., Yeo, S.P. (1995-06). Improved implementation of four-standard procedure for calibrating six-port reflectometers. IEEE Transactions on Instrumentation and Measurement 44 (3) : 632-635. ScholarBank@NUS Repository. https://doi.org/10.1109/19.387297
dc.identifier.issn00189456
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/80574
dc.description.abstractThe present paper describes an improved version of a four-standard calibration procedure for six-port reflectometers that utilizes simple iteration computations instead of the other more cumbersome optimization techniques attempted previously. The four standards required are a matched load (with a return loss not more than -40 dB) and three highly reflecting terminations (each with a return loss not less than -2 dB).
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/19.387297
dc.sourceScopus
dc.typeArticle
dc.contributor.departmentELECTRICAL ENGINEERING
dc.description.doi10.1109/19.387297
dc.description.sourcetitleIEEE Transactions on Instrumentation and Measurement
dc.description.volume44
dc.description.issue3
dc.description.page632-635
dc.description.codenIEIMA
dc.identifier.isiutA1995RB97300003
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

13
checked on Nov 25, 2020

WEB OF SCIENCETM
Citations

11
checked on Nov 25, 2020

Page view(s)

63
checked on Nov 30, 2020

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.