Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.chroma.2011.05.069
Title: Low-density solvent-based solvent demulsification dispersive liquid-liquid microextraction for the fast determination of trace levels of sixteen priority polycyclic aromatic hydrocarbons in environmental water samples
Authors: Guo, L.
Lee, H.K. 
Keywords: Low-density solvent
Polycyclic aromatic hydrocarbons
Solvent demulsification dispersive liquid-liquid microextraction
Issue Date: 5-Aug-2011
Citation: Guo, L., Lee, H.K. (2011-08-05). Low-density solvent-based solvent demulsification dispersive liquid-liquid microextraction for the fast determination of trace levels of sixteen priority polycyclic aromatic hydrocarbons in environmental water samples. Journal of Chromatography A 1218 (31) : 5040-5046. ScholarBank@NUS Repository. https://doi.org/10.1016/j.chroma.2011.05.069
Abstract: For the first time, the low-density solvent-based solvent demulsification dispersive liquid-liquid microextraction was developed for the fast, simple, and efficient determination of 16 priority polycyclic aromatic hydrocarbons (PAHs) in environmental samples followed by gas chromatography-mass spectrometric (GC-MS) analysis. In the extraction procedure, a mixture of extraction solvent (n-hexane) and dispersive solvent (acetone) was injected into the aqueous sample solution to form an emulsion. A demulsification solvent was then injected into the aqueous solution to break up the emulsion, which turned clear and was separated into two layers. The upper layer (n-hexane) was collected and analyzed by GC-MS. No centrifugation was required in this procedure. Significantly, the extraction needed only 2-3. min, faster than conventional DLLME or similar techniques. Another feature of the procedure was the use of a flexible and disposable polyethylene pipette as the extraction device, which permitted a solvent with a density lighter than water to be used as extraction solvent. This novel method expands the applicability of DLLME to a wider range of solvents. Furthermore, the method was simple and easy to use, and some additional steps usually required in conventional DLLME or similar techniques, such as the aforementioned centrifugation, ultrasonication or agitation of the sample solution, or refrigeration of the extraction solvent were not necessary. Important parameters affecting the extraction efficiency were investigated in detail. Under the optimized conditions, the proposed method provided a good linearity in the range of 0.05-50 μg/L, low limits of detection (3.7-39.1. ng/L), and good repeatability of the extractions (RSDs below 11%, n= 5). The proposed method was successfully applied to the extraction of PAHs in rainwater samples, and was demonstrated to be fast, efficient, and convenient. © 2011 Elsevier B.V.
Source Title: Journal of Chromatography A
URI: http://scholarbank.nus.edu.sg/handle/10635/76457
ISSN: 00219673
DOI: 10.1016/j.chroma.2011.05.069
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.