Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/75131
DC FieldValue
dc.titleExperimental studies of mechanically-fastened FRP systems: State-of-the-art
dc.contributor.authorBrown, V.L.
dc.contributor.authorBank, L.C.
dc.contributor.authorArora, D.
dc.contributor.authorBorowicz, D.T.
dc.contributor.authorGodat, A.
dc.contributor.authorLamanna, A.J.
dc.contributor.authorLee, J.
dc.contributor.authorMatta, F.
dc.contributor.authorNapoli, A.
dc.contributor.authorTan, K.H.
dc.date.accessioned2014-06-19T09:18:20Z
dc.date.available2014-06-19T09:18:20Z
dc.date.issued2011
dc.identifier.citationBrown, V.L.,Bank, L.C.,Arora, D.,Borowicz, D.T.,Godat, A.,Lamanna, A.J.,Lee, J.,Matta, F.,Napoli, A.,Tan, K.H. (2011). Experimental studies of mechanically-fastened FRP systems: State-of-the-art. American Concrete Institute, ACI Special Publication 2 (275 SP) : 841-861. ScholarBank@NUS Repository.
dc.identifier.isbn9781618392039
dc.identifier.issn01932527
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/75131
dc.description.abstractSynopsis: A method for strengthening reinforced concrete members using mechanically-fastened FRP (MF-FRP) has been studied in laboratory investigations and in several bridge strengthening demonstration projects. The strengthening is obtained by attaching FRP strips, with high bearing and longitudinal strengths, to concrete elements using steel power actuated fastening "pins" (PAFs), steel anchor bolts or concrete screws, or a combination thereof. The MF-FRP method requires minimal surface preparation and permits immediate use of the strengthened structure. Published research on this method with a range of member sizes has shown promising results in terms of installation efficiency, level of strengthening achieved, and preventing strip delamination before concrete crushing. This State-of-the-Art paper presents an overview of work conducted over the last 10 years on experimental aspects of the MF-FRP method, with beams as well as one-way and two-way slabs. A database of collected test results for MF-FRP strengthened beams and one-way slabs is presented.
dc.sourceScopus
dc.subjectConcrete beams
dc.subjectFiber reinforced polymers
dc.subjectFlexural strengthening
dc.typeConference Paper
dc.contributor.departmentCIVIL & ENVIRONMENTAL ENGINEERING
dc.description.sourcetitleAmerican Concrete Institute, ACI Special Publication
dc.description.volume2
dc.description.issue275 SP
dc.description.page841-861
dc.identifier.isiutNOT_IN_WOS
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.