dc.titleInvestigation of current harmonics in thruster AC drives in oil-rig platforms
dc.contributor.authorYadav, P.
dc.contributor.authorCheah, C.W.
dc.contributor.authorAllana, A.S.
dc.contributor.authorLye, T.
dc.contributor.authorChang, C.S.
dc.contributor.authorPanda, S.K.
dc.contributor.authorSahoo, S.K.
dc.date.accessioned2014-06-19T03:14:54Z
dc.date.available2014-06-19T03:14:54Z
dc.date.issued2009
dc.identifier.citationYadav, P.,Cheah, C.W.,Allana, A.S.,Lye, T.,Chang, C.S.,Panda, S.K.,Sahoo, S.K. (2009). Investigation of current harmonics in thruster AC drives in oil-rig platforms. Proceedings of the International Conference on Power Electronics and Drive Systems : 920-925. ScholarBank@NUS Repository. <a href="https://doi.org/10.1109/PEDS.2009.5385816" target="_blank">https://doi.org/10.1109/PEDS.2009.5385816</a>
dc.identifier.isbn9781424441662
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/70675
dc.description.abstractThe paper investigates the effect of current harmonics in oil-rig's thruster drives, which are based on variable frequency AC induction motor drives. The electrical system in the oil rig consists of two 12 pulse phase shifting transformers having a relative phase shift of 15°, a frequency converter and an induction motor. The electrical system exhibits clean energy characteristics according to IEEE. Std 519.1992 with I-THD of 2.48% and harmonics of the order of 24n±1 at the busbar when both transformers are equally loaded. Due to the nonlinear nature of diode bridge rectifier and dc link capacitors, the input line currents are highly distorted and contain significant amount of low order harmonics causing overheating of the transformer. To investigate the effect of harmonics on the transformer, the mathematical model of the electrical system of oil rig and thermal model of the three windings dry transformer is developed in MATLAB. The temperature rise in the transformer is calculated using IEEE. Std C57.12.91.2001. The test results are investigated and to increase the thermal capability of the transformer, K-factor is calculated and transformer is derated accordingly. The temperature rise decreases with the derating of the transformer and the transformer can now be loaded beyond the nameplate rating upto 1.2 pu load without overheating.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/PEDS.2009.5385816
dc.sourceScopus
dc.subject24-pulse
dc.subjectHarmonics
dc.subjectK factor
dc.subjectThruster drives
dc.typeConference Paper
dc.contributor.departmentELECTRICAL & COMPUTER ENGINEERING
dc.description.doi10.1109/PEDS.2009.5385816
dc.description.sourcetitleProceedings of the International Conference on Power Electronics and Drive Systems
dc.description.page920-925
dc.description.coden85RTA
dc.identifier.isiutNOT_IN_WOS
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Page view(s)

156
checked on Mar 16, 2023

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.