Please use this identifier to cite or link to this item:
https://doi.org/10.1109/BioRob.2012.6290938
DC Field | Value | |
---|---|---|
dc.title | Influence of the skin thickness on tactile shape discrimination | |
dc.contributor.author | Cabibihan, J.-J. | |
dc.contributor.author | Carrozza, M.C. | |
dc.date.accessioned | 2014-06-19T03:13:54Z | |
dc.date.available | 2014-06-19T03:13:54Z | |
dc.date.issued | 2012 | |
dc.identifier.citation | Cabibihan, J.-J.,Carrozza, M.C. (2012). Influence of the skin thickness on tactile shape discrimination. Proceedings of the IEEE RAS and EMBS International Conference on Biomedical Robotics and Biomechatronics : 1681-1685. ScholarBank@NUS Repository. <a href="https://doi.org/10.1109/BioRob.2012.6290938" target="_blank">https://doi.org/10.1109/BioRob.2012.6290938</a> | |
dc.identifier.isbn | 9781457711992 | |
dc.identifier.issn | 21551774 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/70591 | |
dc.description.abstract | Tactile sensors are important for robotic or prosthetic hands, which are designed for manipulation of objects. These sensors are normally embedded in soft, elastic materials for protecting the subsurface sensor from damage or for better hand-to-object contact. In this paper, various thicknesses of the synthetic skin were investigated to determine their effects on the signals that will be detected by the embedded sensor. A finite element model of an artificial fingertip, which was based on viscoelastic and hyperelastic behavior, was used. It was shown that the synthetic skin blurs the signals that are transmitted to the embedded sensor. In short, the thicker the material, the more it will be difficult for the embedded sensor to discriminate the shape that is indented on the surface. These results are helpful to guide the specifications of the skin thickness of artificial skins with embedded tactile sensing. © 2012 IEEE. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/BioRob.2012.6290938 | |
dc.source | Scopus | |
dc.type | Conference Paper | |
dc.contributor.department | ELECTRICAL & COMPUTER ENGINEERING | |
dc.description.doi | 10.1109/BioRob.2012.6290938 | |
dc.description.sourcetitle | Proceedings of the IEEE RAS and EMBS International Conference on Biomedical Robotics and Biomechatronics | |
dc.description.page | 1681-1685 | |
dc.identifier.isiut | NOT_IN_WOS | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
SCOPUSTM
Citations
4
checked on Mar 17, 2023
Page view(s)
137
checked on Mar 16, 2023
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.