Please use this identifier to cite or link to this item:
https://doi.org/10.3390/s131013744
DC Field | Value | |
---|---|---|
dc.title | Development of an amorphous selenium-based photodetector driven by a diamond cold cathode | |
dc.contributor.author | Masuzawa, T. | |
dc.contributor.author | Saito, I. | |
dc.contributor.author | Yamada, T. | |
dc.contributor.author | Onishi, M. | |
dc.contributor.author | Yamaguchi, H. | |
dc.contributor.author | Suzuki, Y. | |
dc.contributor.author | Oonuki, K. | |
dc.contributor.author | Kato, N. | |
dc.contributor.author | Ogawa, S. | |
dc.contributor.author | Takakuwa, Y. | |
dc.contributor.author | Koh, A.T.T. | |
dc.contributor.author | Chua, D.H.C. | |
dc.contributor.author | Mori, Y. | |
dc.contributor.author | Shimosawa, T. | |
dc.contributor.author | Okano, K. | |
dc.date.accessioned | 2014-06-18T06:10:47Z | |
dc.date.available | 2014-06-18T06:10:47Z | |
dc.date.issued | 2013-10-11 | |
dc.identifier.citation | Masuzawa, T., Saito, I., Yamada, T., Onishi, M., Yamaguchi, H., Suzuki, Y., Oonuki, K., Kato, N., Ogawa, S., Takakuwa, Y., Koh, A.T.T., Chua, D.H.C., Mori, Y., Shimosawa, T., Okano, K. (2013-10-11). Development of an amorphous selenium-based photodetector driven by a diamond cold cathode. Sensors (Switzerland) 13 (10) : 13744-13778. ScholarBank@NUS Repository. https://doi.org/10.3390/s131013744 | |
dc.identifier.issn | 14248220 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/68198 | |
dc.description.abstract | Amorphous-selenium (a-Se) based photodetectors are promising candidates for imaging devices, due to their high spatial resolution and response speed, as well as extremely high sensitivity enhanced by an internal carrier multiplication. In addition, a-Se is reported to show sensitivity against wide variety of wavelengths, including visible, UV and X-ray, where a-Se based flat-panel X-ray detector was proposed. In order to develop an ultra high-sensitivity photodetector with a wide detectable wavelength range, a photodetector was fabricated using a-Se photoconductor and a nitrogen-doped diamond cold cathode. In the study, a prototype photodetector has been developed, and its response to visible and ultraviolet light are characterized. © 2013 by the authors; licensee MDPI, Basel, Switzerland. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.3390/s131013744 | |
dc.source | Scopus | |
dc.subject | Amorphous selenium | |
dc.subject | Carrier multiplication | |
dc.subject | Cold cathode | |
dc.subject | Diamond | |
dc.subject | Photodetector | |
dc.type | Review | |
dc.contributor.department | MATERIALS SCIENCE AND ENGINEERING | |
dc.description.doi | 10.3390/s131013744 | |
dc.description.sourcetitle | Sensors (Switzerland) | |
dc.description.volume | 13 | |
dc.description.issue | 10 | |
dc.description.page | 13744-13778 | |
dc.identifier.isiut | 000328625300057 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.