Please use this identifier to cite or link to this item: https://doi.org/10.1007/s10237-011-0344-9
DC FieldValue
dc.titleMechanical behavior of human embryonic stem cell pellet under unconfined compression
dc.contributor.authorMa, G.
dc.contributor.authorPetersen, E.
dc.contributor.authorLeong, K.W.
dc.contributor.authorLiao, K.
dc.date.accessioned2014-06-17T09:45:02Z
dc.date.available2014-06-17T09:45:02Z
dc.date.issued2012-05
dc.identifier.citationMa, G., Petersen, E., Leong, K.W., Liao, K. (2012-05). Mechanical behavior of human embryonic stem cell pellet under unconfined compression. Biomechanics and Modeling in Mechanobiology 11 (5) : 703-714. ScholarBank@NUS Repository. https://doi.org/10.1007/s10237-011-0344-9
dc.identifier.issn16177959
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/67150
dc.description.abstractAs a prelude to the understanding of mechanotransduction in human embryonic stem cell (hESC) differentiation, the mechanical behavior of hESCs in the form of cell pellet is studied. The pellets were tested after 3 or 5weeks of cell culture in order to demonstrate the effect of the duration of cell culture on themechanical properties of the pellets.Amicromechanical testerwas used to conduct unconfined compression on hESC pellet, and experimental, numerical, and analytical methods were combined to determine the mechanical properties of hESC pellet. It is assumed that the mechanical behavior of hESC pellets can be described by an isotropic, linear viscoelastic model consisting of a spring and two Maxwell units in parallel, and the Poisson's ratio of the hESC pellet is constant based on pellet deformation in the direction perpendicular to the compression direction. Finite element method (FEM) simulation was adopted to determine the values of Poisson's ratio and the five parameters contained in the viscoelastic model. The variations of Poisson's ratio and the initial elastic modulus are found to be larger compared with those of the four other parameters. Results show that longer duration of cell culture leads to higher modulus of hESC pellet. The effect of pellet size error on the values of mechanical parameters determined is studied using FEM simulation, and it is found that the effect of size error on Poisson's ratio and initial elastic modulus is much larger than that on the other parameters. © Springer-Verlag 2011.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1007/s10237-011-0344-9
dc.sourceScopus
dc.subjectFinite element method simulation
dc.subjectHuman embryonic stem cell pellet
dc.subjectPoisson's ratio
dc.subjectUnconfined compression
dc.subjectViscoelastic model
dc.typeArticle
dc.contributor.departmentBIOENGINEERING
dc.description.doi10.1007/s10237-011-0344-9
dc.description.sourcetitleBiomechanics and Modeling in Mechanobiology
dc.description.volume11
dc.description.issue5
dc.description.page703-714
dc.identifier.isiut000303378200010
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.