dc.titleImage analysis technique for monitoring early age shrinkage strains with depth from the top surface of monolithic cementitious prism specimens
dc.contributor.authorOng, K.C.G.
dc.contributor.authorChandra, L.R.
dc.date.accessioned2014-06-17T05:30:19Z
dc.date.available2014-06-17T05:30:19Z
dc.date.issued2011-09
dc.identifier.citationOng, K.C.G., Chandra, L.R. (2011-09). Image analysis technique for monitoring early age shrinkage strains with depth from the top surface of monolithic cementitious prism specimens. Journal of Testing and Evaluation 39 (5) : -. ScholarBank@NUS Repository.
dc.identifier.issn00903973
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/59078
dc.description.abstractThis paper describes the use of the image analysis technique for monitoring the variation of early age shrinkage strains with respect to the depth from the top surface of ordinary Portland cement mortar and concrete prism specimens starting as early as 30 min after adding water to the mixture. The applicability of the image analysis technique was demonstrated on both sealed and unsealed cementitious prism specimens. As expected, in situations where the top trowelled surface is protected from moisture loss, the shrinkage strains are similar with depth from the top trowelled surface. On the other hand, magnitudes of shrinkage strains monitored vary with depth when the top trowelled surface is exposed to a dry environment from an early age. The results also showed that the effect of settlements on early age shrinkage strains monitored can be minimized by adopting the current image analysis testing arrangement. Furthermore, when the early age shrinkage strains monitored using the image analysis technique were benchmarked against the results obtained via laser sensors, comparable shrinkage strains values were observed on the sealed prism specimen. On the other hand, the laser sensors were found to provide an "average" value of shrinkage strains that develop across the whole cross section of the unsealed prism specimen. Copyright © 1996-2011 ASTM. All Rights Reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1520/JTE103819
dc.sourceScopus
dc.subjectEarly age
dc.subjectImage analysis
dc.subjectMoisture loss
dc.subjectShrinkage
dc.typeArticle
dc.contributor.departmentCIVIL & ENVIRONMENTAL ENGINEERING
dc.description.sourcetitleJournal of Testing and Evaluation
dc.description.volume39
dc.description.issue5
dc.description.page-
dc.description.codenJTEVA
dc.identifier.isiut000296598400017
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

1
checked on Feb 27, 2018

WEB OF SCIENCETM
Citations

1
checked on Jul 16, 2019

Page view(s)

83
checked on Jun 23, 2021

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.