dc.titleA new normalization method for determination of colloidal fouling potential in membrane processes
dc.contributor.authorSong, L.
dc.contributor.authorChen, K.L.
dc.contributor.authorOng, S.L.
dc.contributor.authorNg, W.J.
dc.date.accessioned2014-06-16T09:32:11Z
dc.date.available2014-06-16T09:32:11Z
dc.date.issued2004-03-15
dc.identifier.citationSong, L., Chen, K.L., Ong, S.L., Ng, W.J. (2004-03-15). A new normalization method for determination of colloidal fouling potential in membrane processes. Journal of Colloid and Interface Science 271 (2) : 426-433. ScholarBank@NUS Repository. https://doi.org/10.1016/j.jcis.2003.12.016
dc.identifier.issn00219797
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/54537
dc.description.abstractNormalization of permeate flux data is widely used to characterize membrane fouling under different experimental conditions. The main intention of normalization is to allow a fair comparison of feed water fouling potentials by eliminating the effects of different operational parameters used in the experiments, such as net driving pressure and clean-membrane resistance. However, it was demonstrated that the commonly used intuitive normalization methods usually could not serve their intended purpose. In this study, a new normalization method was proposed for characterizing water-fouling potential based on fundamental principles of membrane fouling. The intention of this normalization method was to define a fouling potential for feed water that was independent of, or at least, not strongly affected by operational conditions. Laboratory-scale ultrafiltration fouling tests were conducted under different colloid sizes, concentrations, and driving pressures. The experiments showed that the fouling potentials defined by the newly proposed normalization method were linearly related to the colloid concentration of the feed water and that the effect of operational conditions used in the fouling experiments on the fouling potential was minimal. © 2004 Elsevier Inc. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.jcis.2003.12.016
dc.sourceScopus
dc.subjectFouling potential
dc.subjectNormalization
dc.subjectSilica colloids
dc.subjectUltrafiltration
dc.typeArticle
dc.contributor.departmentCIVIL ENGINEERING
dc.description.doi10.1016/j.jcis.2003.12.016
dc.description.sourcetitleJournal of Colloid and Interface Science
dc.description.volume271
dc.description.issue2
dc.description.page426-433
dc.description.codenJCISA
dc.identifier.isiut000189155500022
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

30
checked on Nov 28, 2020

WEB OF SCIENCETM
Citations

31
checked on Nov 20, 2020

Page view(s)

88
checked on Dec 1, 2020

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.