Please use this identifier to cite or link to this item: https://doi.org/10.1016/S0021-9673(98)00126-5
DC FieldValue
dc.titleTrace analysis by combined use of off-line solid-phase extraction, on- column sample focusing and U-shape flow cell in capillary liquid chromatography
dc.contributor.authorHe, Y.
dc.contributor.authorLee, H.K.
dc.date.accessioned2014-05-16T07:37:05Z
dc.date.available2014-05-16T07:37:05Z
dc.date.issued1998-05-29
dc.identifier.citationHe, Y., Lee, H.K. (1998-05-29). Trace analysis by combined use of off-line solid-phase extraction, on- column sample focusing and U-shape flow cell in capillary liquid chromatography. Journal of Chromatography A 808 (1-2) : 79-86. ScholarBank@NUS Repository. https://doi.org/10.1016/S0021-9673(98)00126-5
dc.identifier.issn00219673
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/52723
dc.description.abstractThe potential of capillary liquid chromatography for routine analysis of trace environmental pollutants was demonstrated in the determination of four polycyclic aromatic hydrocarbons (PAHs) at sub-ppb levels in natural water. The method involved the quick conversion of conventional high- performance liquid chromatography capillary LC using a commercially available upgrading kit. Focus was placed on enhancing concentration sensitivity by the combined use of off-line solid-phase extraction (SPE), on-column sample focusing and a U-shaped capillary flow cell. Influencing factors in SPE (sample volume, sorbent, eluent and elution temperature) and sample focusing (injection volume and sample solvent) were investigated together for optimizing overall enrichment. Under optimal conditions, the detection limit was in the range of 0.04-0.2 μg/l for the four PAHs. Sample volume was reduced, evaporation of organic eluent was eliminated, and therefore total analysis time was reduced; recoveries for the PAHs were >84%.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/S0021-9673(98)00126-5
dc.sourceScopus
dc.subjectPolynuclear aromatic hydrocarbons
dc.subjectTrace analysis
dc.typeArticle
dc.contributor.departmentCHEMISTRY
dc.contributor.departmentCHEMICAL ENGINEERING
dc.description.doi10.1016/S0021-9673(98)00126-5
dc.description.sourcetitleJournal of Chromatography A
dc.description.volume808
dc.description.issue1-2
dc.description.page79-86
dc.description.codenJCRAE
dc.identifier.isiut000074138500008
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.