Please use this identifier to cite or link to this item:
https://doi.org/10.1021/la701329r
DC Field | Value | |
---|---|---|
dc.title | Plasma-induced graft copolymerization of poly(methacrylic acid) on electrospun poly(vinylidene fluoride) nanofiber membrane | |
dc.contributor.author | Kaur, S. | |
dc.contributor.author | Ma, Z. | |
dc.contributor.author | Gopal, R. | |
dc.contributor.author | Singh, G. | |
dc.contributor.author | Ramakrishna, S. | |
dc.contributor.author | Matsuura, T. | |
dc.date.accessioned | 2014-04-24T09:36:24Z | |
dc.date.available | 2014-04-24T09:36:24Z | |
dc.date.issued | 2007-12-18 | |
dc.identifier.citation | Kaur, S., Ma, Z., Gopal, R., Singh, G., Ramakrishna, S., Matsuura, T. (2007-12-18). Plasma-induced graft copolymerization of poly(methacrylic acid) on electrospun poly(vinylidene fluoride) nanofiber membrane. Langmuir 23 (26) : 13085-13092. ScholarBank@NUS Repository. https://doi.org/10.1021/la701329r | |
dc.identifier.issn | 07437463 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/51501 | |
dc.description.abstract | Electrospun nanofibrous membranes (ENM) which have a porous structure have a huge potential for various liquid filtration applications. In this paper, we explore the viability of using plasma-induced graft copolymerization to reduce the pore sizes of ENMs. Poly(vinylidene) fluoride (PVDF) was electrospun to produce a nonwoven membrane, comprised of nanofibers with diameters in the range of 200-600 nm. The surface of the ENM was exposed to argon plasma and subsequently graft-copolymerized with methacrylic acid. The effect of plasma exposure time on grafting was studied for both the ENM and a commercial hydrophobic PVDF (HVHP) membrane. The grafting density was quantitatively measured with toluidine blue-O. The degree of grafting increased steeply with an increase in plasma exposure time for the ENM, attaining a maximum of 180 nmol/mg after 120 s of plasma treatment. However, the increase in the grafting density on the surface of the HVHP membrane was not as drastic, reaching a plateau of 65 nmol/mg after 60 s. The liquid entry permeation of water dropped extensively for both membranes, indicating a change in surface properties. Field emission scanning electron microscopy micrographs revealed an alteration in the surface pore structure for both membranes after grafting. Bubble point measurements of the ENM reduced from 3.6 to 0.9 um after grafting. The pore-size distribution obtained using the capillary flow porometer for the grafted ENM revealed that it had a similar profile to that of a commercial hydrophilic commercial PVDF (HVLP) membrane. More significantly, water filtration studies revealed that the grafted ENM had a better flux throughput than the HVLP membrane. This suggests that ENMs can be successfully engineered through surface modification to achieve smaller pores while retaining their high flux performance. © 2007 American Chemical Society. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1021/la701329r | |
dc.source | Scopus | |
dc.type | Article | |
dc.contributor.department | NUS NANOSCIENCE & NANOTECH INITIATIVE | |
dc.contributor.department | MECHANICAL ENGINEERING | |
dc.description.doi | 10.1021/la701329r | |
dc.description.sourcetitle | Langmuir | |
dc.description.volume | 23 | |
dc.description.issue | 26 | |
dc.description.page | 13085-13092 | |
dc.description.coden | LANGD | |
dc.identifier.isiut | 000251583000043 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
SCOPUSTM
Citations
167
checked on May 29, 2023
WEB OF SCIENCETM
Citations
151
checked on May 29, 2023
Page view(s)
256
checked on May 25, 2023
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.