Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.compscitech.2003.09.012
DC FieldValue
dc.titleFibrous composite materials in dentistry and orthopaedics: Review and applications
dc.contributor.authorFujihara, K.
dc.contributor.authorTeo, K.
dc.contributor.authorGopal, R.
dc.contributor.authorLoh, P.L.
dc.contributor.authorGanesh, V.K.
dc.contributor.authorRamakrishna, S.
dc.contributor.authorFoong, K.W.C.
dc.contributor.authorChew, C.L.
dc.date.accessioned2014-04-24T09:33:43Z
dc.date.available2014-04-24T09:33:43Z
dc.date.issued2004-05
dc.identifier.citationFujihara, K., Teo, K., Gopal, R., Loh, P.L., Ganesh, V.K., Ramakrishna, S., Foong, K.W.C., Chew, C.L. (2004-05). Fibrous composite materials in dentistry and orthopaedics: Review and applications. Composites Science and Technology 64 (6) : 775-788. ScholarBank@NUS Repository. https://doi.org/10.1016/j.compscitech.2003.09.012
dc.identifier.issn02663538
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/51414
dc.description.abstractIn this report, the usage of fibrous composite materials in dentistry and orthopaedics is reviewed. Furthermore, the authors introduced functionally graded composite dental post, aesthetic composite archwires and brackets, and braided carbon/PEEK composite compression bone plate. Functionally graded composite dental post has continuously varied stiffness and this function successfully solved stress concentration at the root. Aesthetic composite archwires made of glass /epoxy unidirectional composite has targeted to obtain the highest bending performance by interface control. An epoxysilane coupling agent with 1.0 wt.% solvent showed the highest bending performance. Aesthetic composite bracket has fabricated by braided preform in order to reinforce tie-wing slot where orthodontic force is applied through an archwire. Composite brackets have indicated around 43% mechanical resistance of stainless-steel bracket at tie-wing slot. Bending performance of the braided composite compression bone plates is investigated. The result indicates that the braided composite plate with 2.6 mm thickness can be suitable for forearm treatment whereas the braided composite plate of 3.2 mm thickness is applicable to femur or tibia fixation. © 2003 Elsevier Ltd. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.compscitech.2003.09.012
dc.sourceScopus
dc.subjectA. Textile composites
dc.subjectB. Mechanical properties
dc.subjectC. Finite element analysis
dc.subjectE. Braiding
dc.typeArticle
dc.contributor.departmentBIOENGINEERING
dc.contributor.departmentPREVENTIVE DENTISTRY
dc.contributor.departmentRESTORATIVE DENTISTRY
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1016/j.compscitech.2003.09.012
dc.description.sourcetitleComposites Science and Technology
dc.description.volume64
dc.description.issue6
dc.description.page775-788
dc.description.codenCSTCE
dc.identifier.isiut000221031300001
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.