Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/50962
DC FieldValue
dc.titleKnowledge-driven 3-D extraction of the masseter from MR data.
dc.contributor.authorNg, H.P.
dc.contributor.authorOng, S.H.
dc.contributor.authorFoong, K.W.
dc.contributor.authorGoh, P.S.
dc.contributor.authorNowinski, W.L.
dc.date.accessioned2014-04-24T07:22:29Z
dc.date.available2014-04-24T07:22:29Z
dc.date.issued2006
dc.identifier.citationNg, H.P.,Ong, S.H.,Foong, K.W.,Goh, P.S.,Nowinski, W.L. (2006). Knowledge-driven 3-D extraction of the masseter from MR data.. Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference 1 : 5294-5297. ScholarBank@NUS Repository.
dc.identifier.issn1557170X
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/50962
dc.description.abstractIn this paper, we propose a knowledge-driven highly automatic methodology for extracting the masseter from magnetic resonance (MR) data sets for clinical purposes. The masseter is a muscle of mastication which acts to raise the jaw and clench the teeth. In our initial work, we designed a process which allowed us to perform 2-D segmentation of the masseter on 2-D MR images. In the methodology proposed here, we make use of ground truth to first determine the index of the MR slice in which we will carry out 2-D segmentation of the masseter. Having obtained the 2-D segmentation, we will make use of it to determine the region of interest (ROI) of the masseter in the other MR slices belonging to the same data set. The upper and lower thresholds applied to these MR slices, for extraction of the masseter, are determined through the histogram of the 2-D segmented masseter. Visualization of the 3-D masseter is achieved via volume rendering. Our methodology has been applied to five MR data sets. Validation was done by comparing the segmentation results obtained by using our proposed methodology against manual contour tracings, obtaining an average accuracy of 83.5%
dc.sourceScopus
dc.typeArticle
dc.contributor.departmentPREVENTIVE DENTISTRY
dc.contributor.departmentELECTRICAL & COMPUTER ENGINEERING
dc.contributor.departmentINSTITUTE OF SYSTEMS SCIENCE
dc.description.sourcetitleConference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference
dc.description.volume1
dc.description.page5294-5297
dc.identifier.isiutNOT_IN_WOS
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Page view(s)

108
checked on Mar 16, 2023

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.