Please use this identifier to cite or link to this item: https://doi.org/10.1167/iovs.09-4129
Title: Effect of image quality, color, and format on the measurement of retinal vascular fractal dimension
Authors: Wainwright, A.
Liew, G.
Burlutsky, G.
Rochtchina, E.
Zhang, Y.P.
Hsu, W. 
Lee, J.M.
Wong, T.Y.
Mitchell, P.
Wang, J.J.
Issue Date: 2010
Citation: Wainwright, A., Liew, G., Burlutsky, G., Rochtchina, E., Zhang, Y.P., Hsu, W., Lee, J.M., Wong, T.Y., Mitchell, P., Wang, J.J. (2010). Effect of image quality, color, and format on the measurement of retinal vascular fractal dimension. Investigative Ophthalmology and Visual Science 51 (11) : 5525-5529. ScholarBank@NUS Repository. https://doi.org/10.1167/iovs.09-4129
Abstract: PURPOSE. Fractal dimension of retinal vasculature is a global summary measure of retinal vascular network pattern and geometry. This study was conducted to examine the effect of variations in image color, brightness, focus, contrast, and format on the measurement of retinal vascular fractal dimension. METHODS. A set of 30 retinal images from the Blue Mountains Eye Study was used for a series of experiments by varying brightness, focus (blur), contrast, and color (color versus monochrome). The original and the modified images were graded for fractal dimension (D f) using dedicated retinal imaging software (IRIS-Fractal). A further set of 20 grayscale images was used to compare image format (.jpg versus.tif) with regard to the resultant D f and processing time. RESULTS. The mean D f of original images in this sample was 1.454. Compared with the original set of images, variations in brightness, focus, contrast, and color affected the measurements to a small to moderate degree (Pearson correlation coefficient, r, ranged from 0.47 to 0.97). Very dark or blurry images resulted in a substantially lower estimate of D f. Monochrome images were also consistently associated with lower D f compared with that obtained from color images. Using.jpg or.tif image formats did not affect the measurement or the time needed to process and measure D f. CONCLUSIONS. Variations in image brightness, focus, and contrast can significantly affect the measurement of retinal vascular fractals. Standardization of image parameters and consistent use of either monochrome or color images would reduce measurement noise and enhance the comparability of the results. © Association for Research in Vision and Ophthalmology.
Source Title: Investigative Ophthalmology and Visual Science
URI: http://scholarbank.nus.edu.sg/handle/10635/38907
ISSN: 01460404
DOI: 10.1167/iovs.09-4129
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.