Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.clinph.2010.04.035
DC FieldValue
dc.titleHigh resolution ultrasonography in the diagnosis of ulnar nerve lesions with particular reference to post-traumatic lesions and sites outside the elbow
dc.contributor.authorNg, E.S.
dc.contributor.authorChan, Y.C.
dc.contributor.authorWilder-Smith, E.
dc.contributor.authorVijayan, J.
dc.contributor.authorTherimadasamy, A.K.
dc.contributor.authorTan, T.C.
dc.contributor.authorLim, A.
dc.date.accessioned2011-08-03T01:51:22Z
dc.date.available2011-08-03T01:51:22Z
dc.date.issued2011
dc.identifier.citationNg, E.S., Chan, Y.C., Wilder-Smith, E., Vijayan, J., Therimadasamy, A.K., Tan, T.C., Lim, A. (2011). High resolution ultrasonography in the diagnosis of ulnar nerve lesions with particular reference to post-traumatic lesions and sites outside the elbow. Clinical Neurophysiology 122 (1) : 188-193. ScholarBank@NUS Repository. https://doi.org/10.1016/j.clinph.2010.04.035
dc.identifier.issn13882457
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/25348
dc.description.abstractObjective: Recent studies suggest that high resolution ultrasonography (HRU) is useful in evaluating ulnar neuropathy (UN) at the elbow. These studies do not include UN outside the elbow and lesions related to previous trauma. We investigate diagnostic utility of HRU in UN at any location of traumatic and non-traumatic etiology. Methods: Patients with clinically suspected and electrophysiologically defined UN at the elbow and outside the elbow were included. Nerve conduction studies (NCS) were compared with HRU. HRU defined UN in terms of change in cross-sectional area. Results: Our retrospective analysis included 46 UN. In 25 cases both NCS and HRU localised neuropathy to the elbow. In 15 where NCS was abnormal but non-localising, HRU localised the lesion in 14, 7 outside the elbow. In three of these, HRU characterised further pathology (synovial osteochondromatosis (n = 2), myositis ossificans (n = 1). Cross-sectional area of the ulnar nerve at the sulcus significantly correlated with distal NCS parameters. Conclusions: HRU is of greater use than NCS in the localisation of UN both at the elbow and outside the elbow and in UN related to previous trauma. Significance: HRU is useful for the localisation of ulnar neuropathy. © 2010 International Federation of Clinical Neurophysiology.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.clinph.2010.04.035
dc.sourceScopus
dc.subjectHigh resolution ultrasonography
dc.subjectNerve conduction studies
dc.subjectUlnar nerve
dc.subjectUlnar neuropathy
dc.typeArticle
dc.contributor.departmentMEDICINE
dc.contributor.departmentORTHOPAEDIC SURGERY
dc.description.doi10.1016/j.clinph.2010.04.035
dc.description.sourcetitleClinical Neurophysiology
dc.description.volume122
dc.description.issue1
dc.description.page188-193
dc.identifier.isiut000285406600028
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.