Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/249436
DC FieldValue
dc.title3D COMPUTED TOMOGRAPHY RECONSTRUCTION FROM MICRO-FOCUS X-RAY SYSTEM USING FILTERED BACK-PROJECTION
dc.contributor.authorHANG ZI YING JOANNE
dc.date.accessioned2024-08-13T02:33:40Z
dc.date.available2024-08-13T02:33:40Z
dc.date.issued2024-01-28
dc.identifier.citationHANG ZI YING JOANNE (2024-01-28). 3D COMPUTED TOMOGRAPHY RECONSTRUCTION FROM MICRO-FOCUS X-RAY SYSTEM USING FILTERED BACK-PROJECTION. ScholarBank@NUS Repository.
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/249436
dc.description.abstractTraditional quality checks in manufacturing rely on visual inspection through microscopes, a method prone to human errors and will be a time-consuming process. To address these limitations, irradiating X-ray systems have been widely adopted for 2-dimensional high precision checks on materials and surface defects. However, their inability to conduct 3D inspections has led to the exploration of high precision micro-focus X-ray systems. This paper presents the utilization of a micro-focus X-ray system capable of producing high-resolution images for 3D reconstruction. The micro-focus X-ray source used provides a focus spot size as small as 5µm, which will be able to generate detailed images for 3D tomographic reconstruction. Beyond the small focus spot, meticulous attention has been given to the geometry alignment of the experimental set-up to ensure the accuracy of the 3D data. The proposed 3D Computed Tomography aims to inspect the depth and inner components of the objects, overcoming the limitations of traditional inspection. The reconstruction process employs the Filtered Back Projection algorithm, known for its efficacy in transforming X-ray projections into detailed 3D representations.
dc.language.isoen
dc.subjectCT Reconstruction, Filtered Back Projection, Tomographic, Micro-focus X-ray
dc.typeThesis
dc.contributor.departmentPHYSICS
dc.contributor.supervisorAndrew Anthony Bettiol
dc.contributor.supervisorEdward James Morton
dc.description.degreeMaster's
dc.description.degreeconferredMASTER OF SCIENCE (RSH-FOS)
dc.identifier.orcid0009-0000-4227-8084
Appears in Collections:Master's Theses (Restricted)

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
A0268604Y_Hang Zi Ying Joanne_Master Research Thesis.pdf3.85 MBAdobe PDF

RESTRICTED

NoneLog In

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.