Please use this identifier to cite or link to this item:
https://scholarbank.nus.edu.sg/handle/10635/236767
DC Field | Value | |
---|---|---|
dc.title | A NOVEL DYNAMIC TRACTION SPLINT DESIGN FOR THE MANAGEMENT OF PROXIMAL INTERPHALANGEAL JOINT DORSAL FRACTURE AND DISLOCATION: A FEASIBILITY STUDY | |
dc.contributor.author | HON SUI MING RAYMOND | |
dc.date.accessioned | 2023-01-31T18:06:53Z | |
dc.date.available | 2023-01-31T18:06:53Z | |
dc.date.issued | 2022-02-04 | |
dc.identifier.citation | HON SUI MING RAYMOND (2022-02-04). A NOVEL DYNAMIC TRACTION SPLINT DESIGN FOR THE MANAGEMENT OF PROXIMAL INTERPHALANGEAL JOINT DORSAL FRACTURE AND DISLOCATION: A FEASIBILITY STUDY. ScholarBank@NUS Repository. | |
dc.identifier.uri | https://scholarbank.nus.edu.sg/handle/10635/236767 | |
dc.description.abstract | Proximal interphalangeal joint fracture and dislocation (PIPJ-DFD) is one of the most common PIPJ fractures. While effective in managing PIPJ-DFD, surgical interventions can result in complications such as post-operative scarring and compromised joint function. Conservative approaches require a skilled clinician or splinting practitioner to manually fashion a fitted splint for individual patients for effective treatment. This manual process requires iterations of on-the-spot adjustments and is costly due to the time-consuming process and expertise required. The thesis’s main objectives are to develop a dynamic traction splint design for the management of PIPJ-DFD and to evaluate the feasibility of the developed splint design via cadaveric and mechanical study. A dynamic traction splint was designed and evaluated via mechanical and cadaveric studies. The developed splint design had shown to fulfil the conditions to manage PIPJ-DFD. As observed through radiographic data, the splint had shown potential for the management of unstable PIPJ-DFD non-operatively. Further studies in the form of a clinical trial and a retrospective study are recommended for in-vivo assessment of the splint design. | |
dc.language.iso | en | |
dc.subject | pipj, splint, design, additive manufacturing, 3d printing, parametric design | |
dc.type | Thesis | |
dc.contributor.department | DIVISION OF INDUSTRIAL DESIGN | |
dc.contributor.supervisor | Ching-Chiuan Yen | |
dc.description.degree | Ph.D | |
dc.description.degreeconferred | DOCTOR OF PHILOSOPHY (CDE-IND) | |
dc.identifier.orcid | 0000-0003-1844-3574 | |
Appears in Collections: | Ph.D Theses (Restricted) |
Show simple item record
Files in This Item:
File | Description | Size | Format | Access Settings | Version | |
---|---|---|---|---|---|---|
HonSMR_A0087776H_PhD_Thesis_20221223.pdf | 27.9 MB | Adobe PDF | RESTRICTED | None | Log In |
Google ScholarTM
Check
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.