Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.clinbiochem.2022.03.004
Title: Finding a reliable assay for soluble neprilysin
Authors: Liew, OW 
Prickett, TCR
Revuelta-Lopez, E
Ling, SSM 
Cserkoova, A
Lupon, J
Ng, JYX 
Chong, JPC 
Lilyanna, S 
Chan, SP 
Lin, Q 
Lim, TK
Lin, Q 
Barallat, J
Bayes-Genis, A
Richards, AM 
Keywords: Biomarker research
Commercial research-use-only (RUO) tests
Heart failure
Neprilysin
sNEP
Biomarkers
Enzyme-Linked Immunosorbent Assay
Heart Failure
Humans
Neprilysin
Reproducibility of Results
Spain
Issue Date: 1-Jun-2022
Publisher: Elsevier BV
Citation: Liew, OW, Prickett, TCR, Revuelta-Lopez, E, Ling, SSM, Cserkoova, A, Lupon, J, Ng, JYX, Chong, JPC, Lilyanna, S, Chan, SP, Lin, Q, Lim, TK, Lin, Q, Barallat, J, Bayes-Genis, A, Richards, AM (2022-06-01). Finding a reliable assay for soluble neprilysin. Clinical Biochemistry 104 : 51-58. ScholarBank@NUS Repository. https://doi.org/10.1016/j.clinbiochem.2022.03.004
Abstract: Background: Lack of validation and standardization of research-use-only (RUO) immunoassays brings with it inherent threats to authenticity and functional quality. Poor correlation between different commercial neprilysin RUO immunoassays is concerning and discordant findings need to be resolved. We seek to identify and validate reliable neprilysin immunoassays to strengthen the scientific rigor and reproducibility of neprilysin-related investigation and of biomarker research in general. Methods: Soluble neprilysin (sNEP) concentrations were determined in cohorts (n = 532) from Spain (Cohort 1), New Zealand (NZ, Cohort 2) and Singapore (Cohort 3), using commercial kits from six vendors. Apparent sNEP concentrations were correlated between different assays and with plasma neprilysin activity. Assay reliability was further validated by performance verification, MS analysis and cross-reactivity tests. Results: sNEP in Cohorts 1 and 2 measured concurrently in Spain and NZ showed significant inter-laboratory correlation only for the Aviscera Bioscience sNEP ELISA SK00724-01. Neprilysin concentrations obtained with the R&D systems and SK00724-01 ELISAs correlated with each other but not with neprilysin activity. In Cohort 3, sNEP concentrations from the Perkin Elmer AlphaLISA and Biotechne ELLA assays agreed (r = 0.89) and both correlated with neprilysin activity (r = 0.87, 0.77 respectively). MS analysis detected authentic neprilysin in the AlphaLISA kit calibrator and in antibody pull-down material from human plasma. The AlphaLISA assay performed within acceptable limits (spike and recovery, dilutional linearity, inter- and intra-assay CV) and showed no cross-reactivity against neprilysin substrates and closely-related analogues. Conclusion: AlphaLISA and ELLA assays provide reliable measures of sNEP concentrations. Reliability of other commercial neprilysin assays remains in question.
Source Title: Clinical Biochemistry
URI: https://scholarbank.nus.edu.sg/handle/10635/234484
ISSN: 0009-9120
1873-2933
DOI: 10.1016/j.clinbiochem.2022.03.004
Appears in Collections:Staff Publications
Elements

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Finding a reliable assay for soluble neprilysin.pdfPublished version1.21 MBAdobe PDF

OPEN

PublishedView/Download

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.