dc.titleAcute kidney injury detection using refined and physiological-feature augmented urine output
dc.contributor.authorAlkhairy, Sahar
dc.contributor.authorCeli, Leo A.
dc.contributor.authorFeng, Mengling
dc.contributor.authorZimolzak, Andrew J.
dc.date.accessioned2022-10-12T07:54:28Z
dc.date.available2022-10-12T07:54:28Z
dc.date.issued2021-10-01
dc.identifier.citationAlkhairy, Sahar, Celi, Leo A., Feng, Mengling, Zimolzak, Andrew J. (2021-10-01). Acute kidney injury detection using refined and physiological-feature augmented urine output. Scientific Reports 11 (1) : 19561. ScholarBank@NUS Repository. https://doi.org/10.1038/s41598-021-97735-0
dc.identifier.issn2045-2322
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/232294
dc.description.abstractAcute kidney injury (AKI) is common in the intensive care unit, where it is associated with increased mortality. AKI is often defined using creatinine and urine output criteria. The creatinine-based definition is more reliable but less expedient, whereas the urine output based definition is rapid but less reliable. Our goal is to examine the urine output criterion and augment it with physiological features for better agreement with creatinine-based definitions of AKI. The objectives are threefold: (1) to characterize the baseline agreement of urine output and creatinine definitions of AKI; (2) to refine the urine output criteria to identify the thresholds that best agree with the creatinine-based definition; and (3) to build generalized estimating equation (GEE) and generalized linear mixed-effects (GLME) models with static and time-varying features to improve the accuracy of a near-real-time marker for AKI. We performed a retrospective observational study using data from two independent critical care databases, MIMIC-III and eICU, for critically ill patients who developed AKI in intensive care units. We found that the conventional urine output criterion (6 hr, 0.5 ml/kg/h) has specificity and sensitivity of 0.49 and 0.54 for MIMIC-III database; and specificity and sensitivity of 0.38 and 0.56 for eICU. Secondly, urine output thresholds of 12 hours and 0.6 ml/kg/h have specificity and sensitivity of 0.58 and 0.48 for MIMIC-III; and urine output thresholds of 10 hours and 0.6 ml/kg/h have specificity and sensitivity of 0.49 and 0.48 for eICU. Thirdly, the GEE model of four hours duration augmented with static and time-varying features can achieve a specificity and sensitivity of 0.66 and 0.61 for MIMIC-III; and specificity and sensitivity of 0.66 and 0.64 for eICU. The GLME model of four hours duration augmented with static and time-varying features can achieve a specificity and sensitivity of 0.71 and 0.55 for MIMIC-III; and specificity and sensitivity of 0.66 and 0.60 for eICU. The GEE model has greater performance than the GLME model, however, the GLME model is more reflective of the variables as fixed effects or random effects. The significant improvement in performance, relative to current definitions, when augmenting with patient features, suggest the need of incorporating these features when detecting disease onset and modeling at window-level rather than patient-level. © 2021, The Author(s).
dc.publisherNature Research
dc.rightsAttribution 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceScopus OA2021
dc.typeArticle
dc.contributor.departmentSAW SWEE HOCK SCHOOL OF PUBLIC HEALTH
dc.description.doi10.1038/s41598-021-97735-0
dc.description.sourcetitleScientific Reports
dc.description.volume11
dc.description.issue1
dc.description.page19561
Appears in Collections:Staff Publications
Elements

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_1038_s41598-021-97735-0.pdf2.57 MBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons