dc.titleAccuracy of algorithm to non-invasively predict core body temperature using the kenzen wearable device
dc.contributor.authorMoyen, Nicole E.
dc.contributor.authorBapat, Rohit C.
dc.contributor.authorTan, Beverly
dc.contributor.authorHunt, Lindsey A.
dc.contributor.authorJay, Ollie
dc.contributor.authorMündel, Toby
dc.date.accessioned2022-10-12T07:53:30Z
dc.date.available2022-10-12T07:53:30Z
dc.date.issued2021-12-13
dc.identifier.citationMoyen, Nicole E., Bapat, Rohit C., Tan, Beverly, Hunt, Lindsey A., Jay, Ollie, Mündel, Toby (2021-12-13). Accuracy of algorithm to non-invasively predict core body temperature using the kenzen wearable device. International Journal of Environmental Research and Public Health 18 (24) : 13126. ScholarBank@NUS Repository. https://doi.org/10.3390/ijerph182413126
dc.identifier.issn1661-7827
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/232277
dc.description.abstractWith climate change increasing global temperatures, more workers are exposed to hotter ambient temperatures that exacerbate risk for heat injury and illness. Continuously monitoring core body temperature (TC ) can help workers avoid reaching unsafe TC . However, continuous TC measurements are currently cost-prohibitive or invasive for daily use. Here, we show that Kenzen’s wearable device can accurately predict TC compared to gold standard TC measurements (rectal probe or gastrointestinal pill). Data from four different studies (n = 52 trials; 27 unique subjects; >4000 min data) were used to develop and validate Kenzen’s machine learning TC algorithm, which uses subject’s real-time physiological data combined with baseline anthropometric data. We show Kenzen’s TC algorithm meets pre-established accuracy criteria compared to gold standard TC: mean absolute error = 0.25? C, root mean squared error = 0.30? C, Pearson r correlation = 0.94, standard error of the measurement = 0.18? C, and mean bias = 0.07? C. Overall, the Kenzen TC algorithm is accurate for a wide range of TC, environmental temperatures (13–43? C), light to vigorous heart rate zones, and both biological sexes. To our knowledge, this is the first study demonstrating a wearable device can accurately predict TC in real-time, thus offering workers protection from heat injuries and illnesses. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
dc.publisherMDPI
dc.rightsAttribution 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceScopus OA2021
dc.subjectExtended Kalman filter
dc.subjectHeart rate
dc.subjectHeat illness
dc.subjectHeat injury
dc.subjectHeat stress
dc.subjectMachine learning
dc.typeArticle
dc.contributor.departmentDEAN'S OFFICE (MEDICINE)
dc.description.doi10.3390/ijerph182413126
dc.description.sourcetitleInternational Journal of Environmental Research and Public Health
dc.description.volume18
dc.description.issue24
dc.description.page13126
Appears in Collections:Staff Publications
Elements

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_3390_ijerph182413126.pdf1.42 MBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons