Please use this identifier to cite or link to this item:
https://doi.org/10.1016/bs.mie.2016.04.008
DC Field | Value | |
---|---|---|
dc.title | Strategies for Automated CryoEM Data Collection Using Direct Detectors | |
dc.contributor.author | Cheng, A | |
dc.contributor.author | Tan, YZ | |
dc.contributor.author | Dandey, VP | |
dc.contributor.author | Potter, CS | |
dc.contributor.author | Carragher, B | |
dc.date.accessioned | 2022-06-21T00:29:33Z | |
dc.date.available | 2022-06-21T00:29:33Z | |
dc.date.issued | 2016-01-01 | |
dc.identifier.citation | Cheng, A, Tan, YZ, Dandey, VP, Potter, CS, Carragher, B (2016-01-01). Strategies for Automated CryoEM Data Collection Using Direct Detectors. RESOLUTION REVOLUTION: RECENT ADVANCES IN CRYOEM 579 : 87-102. ScholarBank@NUS Repository. https://doi.org/10.1016/bs.mie.2016.04.008 | |
dc.identifier.issn | 00766879 | |
dc.identifier.issn | 15577988 | |
dc.identifier.uri | https://scholarbank.nus.edu.sg/handle/10635/227220 | |
dc.description.abstract | The new generation of direct electron detectors has been a major contributor to the recent resolution revolution in cryo-electron microscopy. Optimal use of these new cameras using automated data collection software is critical for high-throughput near-atomic resolution cryo-electron microscopy research. We present an overview of the practical aspects of automated data collection in the context of this new generation of direct detectors, highlighting the differences, challenges, and opportunities the new detectors provide compared to the previous generation of data acquisition media. | |
dc.language.iso | en | |
dc.publisher | ELSEVIER ACADEMIC PRESS INC | |
dc.source | Elements | |
dc.subject | Science & Technology | |
dc.subject | Life Sciences & Biomedicine | |
dc.subject | Technology | |
dc.subject | Biochemical Research Methods | |
dc.subject | Biochemistry & Molecular Biology | |
dc.subject | Microscopy | |
dc.subject | BEAM-INDUCED MOTION | |
dc.subject | ELECTRON TOMOGRAPHY | |
dc.subject | MICROSCOPY | |
dc.subject | ALIGNMENT | |
dc.subject | ACQUISITION | |
dc.subject | SPECIMEN | |
dc.subject | QUALITY | |
dc.subject | LEGINON | |
dc.subject | SYSTEM | |
dc.subject | EM | |
dc.type | Review | |
dc.date.updated | 2022-06-18T15:01:49Z | |
dc.contributor.department | DEPT OF BIOLOGICAL SCIENCES | |
dc.description.doi | 10.1016/bs.mie.2016.04.008 | |
dc.description.sourcetitle | RESOLUTION REVOLUTION: RECENT ADVANCES IN CRYOEM | |
dc.description.volume | 579 | |
dc.description.page | 87-102 | |
dc.published.state | Published | |
Appears in Collections: | Staff Publications Elements |
Show simple item record
Files in This Item:
File | Description | Size | Format | Access Settings | Version | |
---|---|---|---|---|---|---|
2016-08-26_Cheng_Methodsinenzymology.pdf | Published version | 905.15 kB | Adobe PDF | CLOSED | None |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.