Please use this identifier to cite or link to this item: https://doi.org/10.3390/JCDD7030037
DC FieldValue
dc.titleDevelopment and disease review left ventricular blood flow kinetic energy assessment by 4d flow cardiovascular magnetic resonance: A systematic review of the clinical relevance
dc.contributor.authorKaur, H
dc.contributor.authorAssadi, H
dc.contributor.authorAlabed, S
dc.contributor.authorCameron, D
dc.contributor.authorVassilios, VS
dc.contributor.authorWestenberg, JJM
dc.contributor.authorGeest, RVD
dc.contributor.authorZhong, L
dc.contributor.authorDastidar, A
dc.contributor.authorSwift, AJ
dc.contributor.authorGarg, P
dc.date.accessioned2022-06-08T00:31:50Z
dc.date.available2022-06-08T00:31:50Z
dc.date.issued2020-09-01
dc.identifier.citationKaur, H, Assadi, H, Alabed, S, Cameron, D, Vassilios, VS, Westenberg, JJM, Geest, RVD, Zhong, L, Dastidar, A, Swift, AJ, Garg, P (2020-09-01). Development and disease review left ventricular blood flow kinetic energy assessment by 4d flow cardiovascular magnetic resonance: A systematic review of the clinical relevance. Journal of Cardiovascular Development and Disease 7 (3) : E37-. ScholarBank@NUS Repository. https://doi.org/10.3390/JCDD7030037
dc.identifier.issn23083425
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/226677
dc.description.abstractBackground: There is an emerging body of evidence that supports the potential clinical value of left ventricular (LV) intracavity blood flow kinetic energy (KE) assessment using four-dimensional flow cardiovascular magnetic resonance imaging (4D flow CMR). The aim of this systematic review is to summarize studies evaluating LV intracavity blood flow KE quantification methods and its potential clinical significance. Methods: A systematic review search was carried out on Medline, Pubmed, EMBASE and CINAHL. Results: Of the 677 articles screened, 16 studies met eligibility. These included six (37%) studies on LV diastolic function, another six (37%) studies on heart failure or cardiomyopathies, three (19%) studies on ischemic heart disease or myocardial infarction and finally, one (6%) study on valvular heart disease, namely, mitral regurgitation. One of the main strengths identified by these studies is high reproducibility of LV blood flow KE hemodynamic assessment (mean coefficient of variability = 6± 2%) for the evaluation of LV diastolic function. Conclusions: The evidence gathered in this systematic review suggests that LV blood flow KE has great promise for LV hemodynamic assessment. Studies showed increased diagnostic confidence at no cost of additional time. Results were highly reproducible with low intraobserver variability.
dc.publisherMDPI AG
dc.sourceElements
dc.subject4D flow CMR
dc.subject4D flow MRI
dc.subjectcardiovascular magnetic resonance
dc.subjectfour-dimensional
dc.subjectintracardiac
dc.subjectphase contrast
dc.subjectsystematic review
dc.subjecttime-resolved
dc.subjectvelocity encoded
dc.typeReview
dc.date.updated2022-06-07T06:15:21Z
dc.contributor.departmentDEAN'S OFFICE (DUKE-NUS MEDICAL SCHOOL)
dc.description.doi10.3390/JCDD7030037
dc.description.sourcetitleJournal of Cardiovascular Development and Disease
dc.description.volume7
dc.description.issue3
dc.description.pageE37-
dc.published.statePublished
Appears in Collections:Staff Publications
Elements

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Left Ventricular Blood Flow Kinetic Energy Assessment by 4D Flow Cardiovascular Magnetic Resonance A Systematic Review of th.pdfPublished version2.3 MBAdobe PDF

OPEN

PublishedView/Download

SCOPUSTM   
Citations

6
checked on Nov 25, 2022

Page view(s)

55
checked on Nov 17, 2022

Download(s)

1
checked on Nov 17, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.