Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/223063
DC FieldValue
dc.titleEVALUATION OF THE PERFORMANCE OF A SMART FAN FILTER UNIT IN IMPROVING IAQ
dc.contributor.authorMYA THWE KO
dc.date.accessioned2020-06-05T10:23:26Z
dc.date.accessioned2022-04-22T18:25:24Z
dc.date.available2020-06-15
dc.date.available2022-04-22T18:25:24Z
dc.date.issued2020-06-05
dc.identifier.citationMYA THWE KO (2020-06-05). EVALUATION OF THE PERFORMANCE OF A SMART FAN FILTER UNIT IN IMPROVING IAQ. ScholarBank@NUS Repository.
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/223063
dc.description.abstractThe performance of a Smart Fan Filter Unit (FFU) in mitigating haze and the resultant hazardous Particulate Matter (PM) levels which affect Indoor Air Quality (IAQ) was assessed in this study. This was examined in a naturally ventilated test-bed environment under trans-boundary haze conditions. The FFU employed provides Air Exchange Rate (ACH) of 4.66 h-1 which aids in improving IAQ. Indoor particle characteristics such as indoor/outdoor ratio (I/O ratio) and filtration efficiency have been used as methods of measuring the benefits provided by the FFU in a naturally ventilated space that is vulnerable to haze. The computed I/O ratio and filtration efficiency suggest that indoor infiltration of PM was significantly reduced due to the use of FFU. The FFU was able to achieve maximum filtration efficiency of 73% for particles sized 2.5 μm. The effectiveness of the FFU in its satisfactory performance can be attributed to its well-designed filtration and exfiltration mechanisms. The FFU’s ability to provide thermal comfort indoors was also explored in this study. The sensor performance of the FFU was measured using Root Mean Square Error (RMSE) for a more in-depth assessment of FFU performance. In summary, this dissertation emphasises the ability of the smart FFU in combatting indoor infiltration of haze by assessing its performance in terms of IAQ, thermal comfort and PM mitigation. The FFU’s role of providing clean air in a naturally ventilated space is highlighted and the study provides an alternative approach for haze mitigation strategies which can be applied during haze episodes.
dc.language.isoen
dc.sourcehttps://lib.sde.nus.edu.sg/dspace/handle/sde/4827
dc.subjectPM exposure
dc.subjectHaze Episodes
dc.subjectFan Filter Unit Performance
dc.subjectHaze Mitigation Measures
dc.subjectTham Kwok Wai
dc.subjectBuilding
dc.subjectPFM
dc.subjectProject and Facilities Management
dc.subject2019/2020 PFM
dc.typeDissertation
dc.contributor.departmentBUILDING
dc.contributor.supervisorTHAM KWOK WAI
dc.description.degreeBachelor's
dc.description.degreeconferredBACHELOR OF SCIENCE (PROJECT AND FACILITIES MANAGEMENT)
dc.embargo.terms2020-06-15
Appears in Collections:Bachelor's Theses

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Mya Thwe Ko 2019-2020_dissertation.pdfDissertation3.33 MBAdobe PDF

RESTRICTED

NoneLog In

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.