Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/222187
DC FieldValue
dc.titleASSESSMENT OF THERMAL COMFORT IN A NATURALLY VENTILATED SPACE: PUBLIC HOUSING (HOUSING AND DEVELOPMENT BOARD BLOCK - HDB BLOCKS)
dc.contributor.authorTAN KAH MIN
dc.date.accessioned2017-05-29T04:14:05Z
dc.date.accessioned2022-04-22T17:59:36Z
dc.date.available2019-09-26T14:14:04Z
dc.date.available2022-04-22T17:59:36Z
dc.date.issued2017-05-29
dc.identifier.citationTAN KAH MIN (2017-05-29). ASSESSMENT OF THERMAL COMFORT IN A NATURALLY VENTILATED SPACE: PUBLIC HOUSING (HOUSING AND DEVELOPMENT BOARD BLOCK - HDB BLOCKS). ScholarBank@NUS Repository.
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/222187
dc.description.abstractIn Singapore, more than 80% of our population is residing in naturally ventilated public housing – Housing and Development Board (HDB) flats. Maintaining thermal comfort in the indoor environment of each unit is difficult due to the tropical climate of Singapore. Therefore, mechanical systems are used to maintain comfort indoor environment for the residents. In this paper, it presents the evaluation of thermal comfort in a naturally ventilated public housing of Singapore. Both field survey and measurement were conducted to document the thermal perception and preference of individual. 264 residents from Hougang and Tampines participated in the survey to determine their thermal satisfaction. The results obtained from both objective and subjective measurements were analysed. Even though the climate in Singapore is hot, more than 80% of the respondents feel that the thermal condition is thermally acceptable. Regression model has been applied to determine the correlation between the factors and Thermal Sensation Votes (TSV). Thermal comfort model was also derived by running a Multiple Linear Regression between the dependent and independent variables. Since Operative Temperature (Top) is a more accurate way to determining the temperature felt by the occupants, the relationship between the TSV and Top is studied. The mean TSV was plotted against Top to predict the neutral Top. The result suggests that the thermal comfort model is in line with previous thermal comfort studies.
dc.language.isoen
dc.sourcehttps://lib.sde.nus.edu.sg/dspace/handle/sde/3742
dc.subjectBuilding
dc.subjectPFM
dc.subjectProject and Facilities Management
dc.subjectWong Nyuk Hien
dc.subject2016/2017 PFM
dc.subjectIndoor
dc.subjectNaturally Ventilated
dc.subjectPublic Housing - HDB
dc.subjectThermal Comfort
dc.subjectTropics
dc.typeDissertation
dc.contributor.departmentBUILDING
dc.contributor.supervisorWONG NYUK HIEN
dc.description.degreeBachelor's
dc.description.degreeconferredBACHELOR OF SCIENCE (PROJECT AND FACILITIES MANAGEMENT)
dc.embargo.terms2017-06-02
Appears in Collections:Bachelor's Theses

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Tan Kah Min 2016-2017.pdf3.32 MBAdobe PDF

RESTRICTED

NoneLog In

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.