dc.titleASSESSMENT OF THE INDOOR ENVIRONMENTAL QUALITY OF THE SEMINAR ROOMS IN SCHOOL OF DESIGN AND ENVIRONMENT BUILDINGS
dc.contributor.authorQUAH CHI HSIEN SYLVESTER
dc.date.accessioned2012-06-07T03:07:44Z
dc.date.accessioned2022-04-22T17:58:44Z
dc.date.available2019-09-26T14:14:04Z
dc.date.available2022-04-22T17:58:44Z
dc.date.issued2012-06-07
dc.identifier.citationQUAH CHI HSIEN SYLVESTER (2012-06-07). ASSESSMENT OF THE INDOOR ENVIRONMENTAL QUALITY OF THE SEMINAR ROOMS IN SCHOOL OF DESIGN AND ENVIRONMENT BUILDINGS. ScholarBank@NUS Repository.
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/222155
dc.description.abstractIndoor Environmental Quality (IEQ) refers to all impacts of the indoor environment on human health and performance, including indoor air quality, day lighting and views, and visual and thermal comfort. The increasing emphasis of IEQ can be seen in Singapore, whereby the government set up guidelines and standards to achieve good IEQ. This is evidenced by the recent emergence of BCA Green Mark for Existing Schools Version 1.0. This study aimed to investigate the IEQ of the seminar rooms (SR) located at the School of Design and Environment (SDE) in National University Singapore (NUS) and compare the results with the current local established standards and guidelines. Objective and subjective measurements were carried out in SR 12 and SR 4 of SDE. The objective measurement includes measurement of operative temperature, relative humidity, Total Volatile Organic Compounds (TVOC), particulate matter, total mould and bacterial counts, air velocity, concentration of carbon dioxide (CO2) and carbon monoxide (CO), lighting and the sound level of the SRs. The Subjective measurement includes interviews and questionnaire survey. The operative temperature, air velocity and bacteria counts were found to fail to meet the threshold level during the experiment. Results from the subjective assessment revealed the top three sick building syndromes experienced are dry or irritated throat, dry eyes and block or stuffy nose. In addition, a small number of the respondents felt worse for the symptoms they experienced during their stay in the seminar rooms In conclusion, majority of the respondents were satisfied with the IEQ in the seminar rooms based on the respondents’ perception on the overall satisfactory level for the thermal comfort, indoor air quality, lighting and sound level of seminar rooms. Recommendations to improve the IEQ of the seminar rooms have also been made.
dc.language.isoen
dc.sourcehttps://lib.sde.nus.edu.sg/dspace/handle/sde/1987
dc.subjectBuilding
dc.subjectProject and Facilities Management
dc.subjectChandra Sekhar
dc.subject2011/2012 PFM
dc.typeDissertation
dc.contributor.departmentBUILDING
dc.contributor.supervisorCHANDRA SEKHAR
dc.description.degreeBachelor's
dc.description.degreeconferredBACHELOR OF SCIENCE (PROJECT AND FACILITIES MANAGEMENT)
dc.embargo.terms2012-07-01
Appears in Collections:Bachelor's Theses

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Quah Chi Hsien Sylvester 2011-2012.pdf2.83 MBAdobe PDF

RESTRICTED

NoneLog In

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.