Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/221795
DC FieldValue
dc.titleINDOOR AIR QUALITY IN A FOOD COURT
dc.contributor.authorSONG JIAHUI
dc.date.accessioned2010-12-09T03:04:36Z
dc.date.accessioned2022-04-22T17:48:36Z
dc.date.available2019-09-26T14:14:02Z
dc.date.available2022-04-22T17:48:36Z
dc.date.issued2010-12-09
dc.identifier.citationSONG JIAHUI (2010-12-09). INDOOR AIR QUALITY IN A FOOD COURT. ScholarBank@NUS Repository.
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/221795
dc.description.abstractDining in air-conditioned food establishments such as food courts has been a lifestyle choice for many Singaporeans. However, little research is done to analyse the indoor air quality (IAQ) of these premises. This study seeks to examine the IAQ of an air-conditioned food court located in an office complex. Objective measurements indicate that IAQ level during peak periods have much room for improvement. High concentration of respirable particulate matter, PM10 and PM2.5, were detected. It was found that operative temperature and relative humidity were unable to meet IAQ standards used in governing air-conditioned premises, during most of the peak periods which led to a warm and humid indoor environment. Results from the subjective assessment revealed varied responses of acceptability of the thermal environments with about 70% of respondents feeling thermally comfortable in the food court. Although most respondents perceived the IAQ of food court as acceptable, the presence of odour and acceptability of the thermal environment seem to influence occupants' perceptions. Inadequate ventilation in the food court could have led to the build-up of indoor contaminants. Various recommendations have been made to improve the IAQ and thermal comfort for majority of the people.
dc.language.isoen
dc.sourcehttps://lib.sde.nus.edu.sg/dspace/handle/sde/1328
dc.subjectBuilding
dc.subjectProject and Facilities Management
dc.subjectCheong Kok Wai David
dc.subject2010/2011 PFM
dc.subjectAir-conditioning
dc.subjectFood court
dc.subjectIndoor air quality
dc.subjectThermal comfort
dc.subjectVentilation
dc.typeDissertation
dc.contributor.departmentBUILDING
dc.contributor.supervisorCHEONG KOK WAI DAVID
dc.description.degreeBachelor's
dc.description.degreeconferredBACHELOR OF SCIENCE (PROJECT AND FACILITIES MANAGEMENT)
dc.embargo.terms2010-12-30
Appears in Collections:Bachelor's Theses

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Song Jiahui 2010-2011.pdf2.55 MBAdobe PDF

RESTRICTED

NoneLog In

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.