Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/220536
DC FieldValue
dc.titleINDOOR ENVIRONMENT QUALITY AND OCCUPANT RESPONSES OF AN OFFICE SPACE IN A NON-GREEN MARK CERTIFIED COMMERCIAL BUILDING IN SINGAPORE
dc.contributor.authorLIM SI LING
dc.date.accessioned2012-06-25T07:41:20Z
dc.date.accessioned2022-04-22T17:11:31Z
dc.date.available2019-09-26T14:13:56Z
dc.date.available2022-04-22T17:11:31Z
dc.date.issued2012-06-25
dc.identifier.citationLIM SI LING (2012-06-25). INDOOR ENVIRONMENT QUALITY AND OCCUPANT RESPONSES OF AN OFFICE SPACE IN A NON-GREEN MARK CERTIFIED COMMERCIAL BUILDING IN SINGAPORE. ScholarBank@NUS Repository.
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/220536
dc.description.abstractThis research project aims at studying the Indoor Environmental Quality (IEQ) of a non-green mark certified office space located in an old commercial building and the impact it has on the occupants. It is postulated that green mark certification is not necessary for achieving satisfactory IEQ. The study was done by taking objective and spot measurements from five different selected indoor sampling locations twice on a weekday, in the morning and afternoon. These objective parameters measured include carbon dioxide (CO2), carbon monoxide (CO), Total Volatile Organic Compounds (TVOC), Formaldehyde (HCHO), particulate matter, biological contaminants, temperature, relative humidity, air velocity, air exchange efficiency, air change rate per hour, light and acoustic. These parameters are then compared against the acceptable threshold limits in accordance to the Code of Practice for Indoor Air Quality for Air-Conditioned buildings under SS554:2009, Code of Practice for Air-conditioning and mechanical ventilation for buildings under SS553:2009 and Code of Practice of light for work place under SS531:2009. There was also a subjective measurement carried out on the occupants to identify the effects of the above stated objective parameter through conducting a questionnaire. The findings were mostly within the acceptable limits of threshold except for a few IEQ parameters. Overall, the office space had a satisfactory IEQ based on objective results.
dc.language.isoen
dc.sourcehttps://lib.sde.nus.edu.sg/dspace/handle/sde/2059
dc.subjectBuilding
dc.subjectProject and Facilities Management
dc.subjectTham Kwok Wai
dc.subject2011/2012 PFM
dc.subjectPFM
dc.typeDissertation
dc.contributor.departmentBUILDING
dc.contributor.supervisorTHAM KWOK WAI
dc.description.degreeBachelor's
dc.description.degreeconferredBACHELOR OF SCIENCE (PROJECT AND FACILITIES MANAGEMENT)
dc.embargo.terms2012-07-01
Appears in Collections:Bachelor's Theses

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Lim Si Ling 2011-2012.pdf89.58 MBAdobe PDF

RESTRICTED

NoneLog In

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.