Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/220156
DC FieldValue
dc.titleTHERMAL TRANSIENT SENSATIONS UNDER DIFFERENT ENVIRONMENTAL CONDITIONS
dc.contributor.authorONG WEI QI KEN
dc.date.accessioned2017-06-02T08:39:11Z
dc.date.accessioned2022-04-22T15:54:30Z
dc.date.available2019-09-26T14:13:54Z
dc.date.available2022-04-22T15:54:30Z
dc.date.issued2017-06-02
dc.identifier.citationONG WEI QI KEN (2017-06-02). THERMAL TRANSIENT SENSATIONS UNDER DIFFERENT ENVIRONMENTAL CONDITIONS. ScholarBank@NUS Repository.
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/220156
dc.description.abstractEnergy consumption through air-conditioning is a critical issue to building owners in tropical countries. Thermal transient sensation is important because it affects the thermal exposure from outdoor to indoor condition. However, little to none has been done to understand thermal transient sensation and how it affects our daily lives, especially in an educational institution perspective. Thus, this study on thermal transient sensation is conducted. 20 students have participated in this experiment. The optimal condition to achieve a balance between energy savings and productivity is 26°C with fan. Additionally, air movement was found to have an influence in thermal sensation, especially in warmer indoor conditions. There was a significant difference in the thermal transient sensations at 23°C against 26°C, without fans, but not for 23°C without fan and 26°C with fan. The perspiration rate was found to have higher significance of coefficient correlation to thermal sensation only at the initial stage of 23°C without fan. Furthermore, subjects increase their fan speeds at warmer temperature when experiencing the same thermal sensation. This study finds how air movement may compensate for higher temperature which defrays the widely conceived theory of 26°C being the optimal temperature for student. Implications for energy-saving strategies can be created for future research to building owners, especially to education institution.
dc.language.isoen
dc.sourcehttps://lib.sde.nus.edu.sg/dspace/handle/sde/3777
dc.subjectBuilding
dc.subjectPFM
dc.subjectProject and Facilities Management
dc.subjectTham Kwok Wai
dc.subject2016/2017 PFM
dc.subjectActive behaviour
dc.subjectPerspiration rate
dc.subjectThermal sensation
dc.subjectThermal transient condition
dc.subjectThermal transient sensation
dc.typeDissertation
dc.contributor.departmentBUILDING
dc.contributor.supervisorTHAM KWOK WAI
dc.description.degreeBachelor's
dc.description.degreeconferredBACHELOR OF SCIENCE (PROJECT AND FACILITIES MANAGEMENT)
dc.embargo.terms2017-06-05
Appears in Collections:Bachelor's Theses

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Ong Wei Qi Ken 2016-2017.pdfDissertation2.99 MBAdobe PDF

RESTRICTED

NoneLog In

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.