Citation: ALIOTO,MASSIMO BRUNO, ORAZIO AIELLO (2021-02-13). Capacitance-to-Digital Converter for Operation Under Uncertain Harvested Voltage down to 0.3V with No Trimming, Reference and Voltage Regulation. Capacitance-to-Digital Converter for Operation Under Uncertain Harvested Voltage down to 0.3V with No Trimming, Reference and Voltage Regulation. ScholarBank@NUS Repository. https://doi.org/10.1109/ISSCC42613.2021.9365846
Rights: CC0 1.0 Universal
Abstract: In low-cost battery-less systems, capacitive sensing via capacitance-to-digital conversion (CDC) needs to operate with minimal or no support from additional circuitry such as voltage regulation, voltage/current references or digital post-processing as shown in Fig. 5.2.1 (e.g., for linearization). At the same time, direct harvesting demands operation down to very low voltages and power, to consistently fit the power available from the environment even when scarce (e.g., down to ~nW/mm 2 in light harvesters under realistic conditions). To enable continuous monitoring at power lower than the μW-range of state-of-the-art ~12-bit CDCs [1-3], 7-to-8-bit architectures with power down to sub-nW have been demonstrated for sensor nodes [4], although their supply voltage requirement (≥0.6V) is not suitable for direct harvesting, similar to [5]. CDCs for continuous monitoring at lower resolution (~7 bit) with sub-nW operation at 0.6V have been also demonstrated [6], although their power is burdened by the additional contribution of digital post-processing (~nWs) and others. A fully digital CDC has been introduced in [7] in the form of capacitance-to-voltage conversion via capacitor linear discharge due to a ring oscillator and final voltage-to-digital conversion, which requires two supply voltages of 0.45V and 1V. Operation at minimal power also comes with measurement times in the sub-second or second scale [6,8] in addition to the reduced resolution, which are still in the range required by continuous monitoring in several applications [6,8] (e.g., temperature, humidity, proximity, fluid level monitoring).
Source Title: Capacitance-to-Digital Converter for Operation Under Uncertain Harvested Voltage down to 0.3V with No Trimming, Reference and Voltage Regulation
URI: https://scholarbank.nus.edu.sg/handle/10635/216938
DOI: 10.1109/ISSCC42613.2021.9365846
Rights: CC0 1.0 Universal
Appears in Collections:Staff Publications
Elements

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
CDC.pdf673.5 kBAdobe PDF

CLOSED

Published

SCOPUSTM   
Citations

7
checked on Sep 23, 2022

Page view(s)

58
checked on Sep 22, 2022

Download(s)

1
checked on Sep 22, 2022

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons