Please use this identifier to cite or link to this item:
https://doi.org/10.1109/ACCESS.2019.2891952
DC Field | Value | |
---|---|---|
dc.title | Safety-Enhanced Model-Free Visual Servoing for Continuum Tubular Robots Through Singularity Avoidance in Confined Environments | |
dc.contributor.author | Wu, K. | |
dc.contributor.author | Zhu, G. | |
dc.contributor.author | Wu, L. | |
dc.contributor.author | Gao, W. | |
dc.contributor.author | Song, S. | |
dc.contributor.author | Lim, C.M. | |
dc.contributor.author | Ren, H. | |
dc.date.accessioned | 2021-12-06T04:28:20Z | |
dc.date.available | 2021-12-06T04:28:20Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | Wu, K., Zhu, G., Wu, L., Gao, W., Song, S., Lim, C.M., Ren, H. (2019). Safety-Enhanced Model-Free Visual Servoing for Continuum Tubular Robots Through Singularity Avoidance in Confined Environments. IEEE Access 7 : 21539-21558. ScholarBank@NUS Repository. https://doi.org/10.1109/ACCESS.2019.2891952 | |
dc.identifier.issn | 2169-3536 | |
dc.identifier.uri | https://scholarbank.nus.edu.sg/handle/10635/209626 | |
dc.description.abstract | Minimally invasive procedures have gained ever-increasing popularity due to their advantages of smaller incisions, faster recoveries, fewer complications, and reduced scarring to name a few. With the force exertion and curvilinear flexibility at their distal end effectors, the continuum tubular robots have the potential to perform robot-assisted trans-orifice minimally invasive surgery, such as transnasal and transoral operations. During these procedures, it is important and challenging for the continuum tubular robot to automatically adjust its pose according to the target surgical sites and compensate for undesired disturbance, such as respiratory motions. In this paper, a singularity-avoidance visual servoing algorithm based on Jacobian Optimization has been proposed to improve safety and control continuum tubular robots based on intra-operative visual feedback in confined environments. Without the prior knowledge of robot kinematics or hand-eye calibration between the robot and the endoscope, the proposed model-free eye-in-hand visual servoing technique is capable of accomplishing the targeting tasks by adopting the safety-enhanced singularity avoidance mechanism and an efficient image-processing algorithm. The multiple experiments, including simulations, experiments conducted in a confined environment, and cadaveric studies, have been implemented and demonstrated to illustrate the superiority of the proposed singularity-avoidance visual servoing method. © 2019 IEEE. | |
dc.publisher | Institute of Electrical and Electronics Engineers Inc. | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.source | Scopus OA2019 | |
dc.subject | concentric tube robots | |
dc.subject | continuum tubular robots | |
dc.subject | image processing | |
dc.subject | minimally invasive surgery | |
dc.subject | model-free | |
dc.subject | singularity-avoidance | |
dc.subject | singularity-resistant | |
dc.subject | Visual servoing | |
dc.type | Article | |
dc.contributor.department | DEPT OF BIOMEDICAL ENGINEERING | |
dc.contributor.department | BIOMEDICAL ENGINEERING | |
dc.description.doi | 10.1109/ACCESS.2019.2891952 | |
dc.description.sourcetitle | IEEE Access | |
dc.description.volume | 7 | |
dc.description.page | 21539-21558 | |
Appears in Collections: | Elements Staff Publications |
Show simple item record
Files in This Item:
File | Description | Size | Format | Access Settings | Version | |
---|---|---|---|---|---|---|
10_1109_ACCESS_2019_2891952.pdf | 3.24 MB | Adobe PDF | OPEN | None | View/Download |
SCOPUSTM
Citations
27
checked on Mar 30, 2023
Page view(s)
86
checked on Mar 30, 2023
Google ScholarTM
Check
Altmetric
This item is licensed under a Creative Commons License