dc.titlePerformance evaluation of misting fans in hot and humid climate
dc.contributor.authorWong, N.H.
dc.contributor.authorChong, A.Z.M.
dc.date.accessioned2021-06-09T01:11:37Z
dc.date.available2021-06-09T01:11:37Z
dc.date.issued2010-12-01
dc.identifier.citationWong, N.H., Chong, A.Z.M. (2010-12-01). Performance evaluation of misting fans in hot and humid climate. BUILDING AND ENVIRONMENT 45 (12) : 2666-2678. ScholarBank@NUS Repository.
dc.identifier.issn0360-1323
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/191892
dc.description.abstractSingapore experiences a hot and humid climate throughout the year. This in turn results in heavy reliance on mechanical systems especially air-conditioning to achieve thermal comfort. An alternative would be the use of evaporative cooling which is less energy intensive. Objective and subjective measurements were conducted at an experimental setup at the National University of Singapore (NUS) to evaluate the thermal conditions and thermal sensations brought about by misting fans. Field measurements were also conducted at food centres in Singapore to determine if they are coherent with the objective and subjective measurements conducted. Analysis of objective and subjective data showed that the misting fan was able to significantly reduce the dry-bulb temperature and thermal sensation votes. This is consistent with field measurements taken, where regression analysis showed that with the misting fan, thermal neutrality can be obtained at a higher outdoor effective temperature (ET*). However, the reduction in temperature comes at the expense of higher relative humidity which results in consistently greater biological (bacterial and fungal) pollutants being enumerated from samples collected under the misting fan system. In some samples, the bacteria count is very much greater than samples collected under the non-misting fan, illustrating the potential for a substantial increase in biological pollutants due to the generation of mists. © 2010 Elsevier Ltd.
dc.description.urihttps://doi.org/10.1016/j.buildenv.2010.05.026
dc.language.isoen
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.sourceElements
dc.subjectScience & Technology
dc.subjectTechnology
dc.subjectConstruction & Building Technology
dc.subjectEngineering, Environmental
dc.subjectEngineering, Civil
dc.subjectEngineering
dc.subjectMisting fan
dc.subjectEvaporative cooling
dc.subjectSingapore
dc.subjectHot
dc.subjectHumid
dc.subjectEVAPORATIVE COOLING SYSTEM
dc.subjectAIR-COOLED CHILLERS
dc.subjectENVIRONMENTS
dc.typeArticle
dc.date.updated2021-06-08T08:04:10Z
dc.contributor.departmentDEPT OF BUILDING
dc.description.sourcetitleBUILDING AND ENVIRONMENT
dc.description.volume45
dc.description.issue12
dc.description.page2666-2678
dc.description.codenBUEND
dc.identifier.isiut000281326800008
dc.description.placeUNITED KINGDOM
dc.published.statePublished
Appears in Collections:Staff Publications
Elements

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Performance-evaluation-of-misting-fans-in-hot-and-h_2010_Building-and-Enviro.pdfPublished version2.39 MBAdobe PDF

CLOSED

Published

WEB OF SCIENCETM
Citations

39
checked on Oct 5, 2021

Page view(s)

166
checked on Mar 16, 2023

Download(s)

1
checked on Mar 16, 2023

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.