Please use this identifier to cite or link to this item: https://doi.org/10.1186/1752-153X-7-104
Title: Ultra high performance liquid chromatography tandem mass spectrometry for rapid analysis of trace organic contaminants in water
Authors: Anumol, T
Merel, S
Clarke, B.O
Snyder, S.A 
Issue Date: 2013
Citation: Anumol, T, Merel, S, Clarke, B.O, Snyder, S.A (2013). Ultra high performance liquid chromatography tandem mass spectrometry for rapid analysis of trace organic contaminants in water. Chemistry Central Journal 7 (1) : 104. ScholarBank@NUS Repository. https://doi.org/10.1186/1752-153X-7-104
Rights: Attribution 4.0 International
Abstract: Background: The widespread utilization of organic compounds in modern society and their dispersion through wastewater have resulted in extensive contamination of source and drinking waters. The vast majority of these compounds are not regulated in wastewater outfalls or in drinking water while trace amounts of certain compounds can impact aquatic wildlife. Hence it is prudent to monitor these contaminants in water sources until sufficient toxicological data relevant to humans becomes available. A method was developed for the analysis of 36 trace organic contaminants (TOrCs) including pharmaceuticals, pesticides, steroid hormones (androgens, progestins, and glucocorticoids), personal care products and polyfluorinated compounds (PFCs) using a single solid phase extraction (SPE) technique with ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). The method was applied to a variety of water matrices to demonstrate method performance and reliability.Results: UHPLC-MS/MS in both positive and negative electrospray ionization (ESI) modes was employed to achieve optimum sensitivity while reducing sample analysis time (<20 min) compared with previously published methods. The detection limits for most compounds was lower than 1.0 picogram on the column while reporting limits in water ranged from 0.1 to 15 ng/L based on the extraction of a 1 L sample and concentration to 1 mL. Recoveries in ultrapure water for most compounds were between 90-110%, while recoveries in surface water and wastewater were in the range of 39-121% and 38-141% respectively. The analytical method was successfully applied to analyze samples across several different water matrices including wastewater, groundwater, surface water and drinking water at different stages of the treatment. Among several compounds detected in wastewater, sucralose and TCPP showed the highest concentrations.Conclusion: The proposed method is sensitive, rapid and robust; hence it can be used to analyze a large variety of trace organic compounds in different water matrixes. © 2013 Anumol et al.; licensee Chemistry Central Ltd.
Source Title: Chemistry Central Journal
URI: https://scholarbank.nus.edu.sg/handle/10635/181813
ISSN: 1752153X
DOI: 10.1186/1752-153X-7-104
Rights: Attribution 4.0 International
Appears in Collections:Staff Publications
Elements

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_1186_1752-153X-7-104.pdf881.82 kBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons