Please use this identifier to cite or link to this item:
https://doi.org/10.1128/JCM.00975-17
DC Field | Value | |
---|---|---|
dc.title | Evaluation of a novel reporter virus neutralization test for serological diagnosis of Zika and Dengue virus infection | |
dc.contributor.author | Shan, C | |
dc.contributor.author | Ortiz, D.A | |
dc.contributor.author | Yang, Y | |
dc.contributor.author | Wong, S.J | |
dc.contributor.author | Kramer, L.D | |
dc.contributor.author | Shi, P.-Y | |
dc.contributor.author | Loeffelholz, M.J | |
dc.contributor.author | Ren, P | |
dc.date.accessioned | 2020-10-22T07:36:21Z | |
dc.date.available | 2020-10-22T07:36:21Z | |
dc.date.issued | 2017 | |
dc.identifier.citation | Shan, C, Ortiz, D.A, Yang, Y, Wong, S.J, Kramer, L.D, Shi, P.-Y, Loeffelholz, M.J, Ren, P (2017). Evaluation of a novel reporter virus neutralization test for serological diagnosis of Zika and Dengue virus infection. Journal of Clinical Microbiology 55 (10) : 3028-3036. ScholarBank@NUS Repository. https://doi.org/10.1128/JCM.00975-17 | |
dc.identifier.issn | 00951137 | |
dc.identifier.uri | https://scholarbank.nus.edu.sg/handle/10635/179088 | |
dc.description.abstract | Currently, the laboratory diagnosis of Zika virus (ZIKV) infection is primarily through the detection of ZIKV RNA or antibodies against ZIKV proteins. The detection of viral RNA is highly sensitive and specific, but periods of viremia and viruria are brief, limiting the utility of ZIKV RNA assays. Instead, most ZIKV infections are diagnosed serologically, using an IgM antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) for screening, followed by a confirmatory plaque reduction neutralization test (PRNT). Typical turnaround times vary, due to assay incubation periods and a lack of clinical laboratories performing these tests. Recently, a novel luciferase-ZIKV-and-dengue virus (DENV)-based serological assay, which considerably improves the turnaround times and throughput for ZIKV diagnosis, was described. Using the traditional PRNT as a reference method, we evaluated the performance characteristics of the reporter virus neutralization test (RVNT) with 258 clinical serum specimens. The ZIKV RVNT produced primary ZIKV screening and secondary confirmation results in 4 days, with 100% reproducibility. As a screening assay, the ZIKV RVNT displayed excellent diagnostic accuracy, sensitivity, and specificity of 98.2%, 100%, and 98.1%, respectively. As a confirmatory assay, the ZIKV RVNT titers displayed 93.1% agreement with the traditional ZIKV PRNT titers. Overall, the RVNT accurately and reliably detects neutralizing antibodies in patient serum specimens, with improved turnaround times, and can be used for the serological detection of ZIKV infections. Due to the homogeneous 96-well format, the RVNT has also significantly improved the assay throughput to allow testing of a large number of specimens in a single run. © 2017 Shan et al. | |
dc.publisher | American Society for Microbiology | |
dc.rights | Attribution 4.0 International | |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
dc.source | Unpaywall 20201031 | |
dc.subject | immunoglobulin G antibody | |
dc.subject | immunoglobulin M antibody | |
dc.subject | neutralizing antibody | |
dc.subject | immunoglobulin M | |
dc.subject | neutralizing antibody | |
dc.subject | virus antibody | |
dc.subject | antibody titer | |
dc.subject | Article | |
dc.subject | controlled study | |
dc.subject | dengue | |
dc.subject | diagnostic accuracy | |
dc.subject | diagnostic test accuracy study | |
dc.subject | high risk patient | |
dc.subject | human | |
dc.subject | low risk patient | |
dc.subject | major clinical study | |
dc.subject | plaque reduction neutralization test | |
dc.subject | priority journal | |
dc.subject | reporter virus neutralization test | |
dc.subject | reproducibility | |
dc.subject | screening test | |
dc.subject | sensitivity and specificity | |
dc.subject | serodiagnosis | |
dc.subject | turnaround time | |
dc.subject | virus neutralization | |
dc.subject | Zika fever | |
dc.subject | animal | |
dc.subject | blood | |
dc.subject | cell line | |
dc.subject | Chlorocebus aethiops | |
dc.subject | dengue | |
dc.subject | Dengue virus | |
dc.subject | enzyme linked immunosorbent assay | |
dc.subject | immunology | |
dc.subject | procedures | |
dc.subject | serodiagnosis | |
dc.subject | Vero cell line | |
dc.subject | viremia | |
dc.subject | virology | |
dc.subject | Zika fever | |
dc.subject | Zika virus | |
dc.subject | Animals | |
dc.subject | Antibodies, Neutralizing | |
dc.subject | Antibodies, Viral | |
dc.subject | Cell Line | |
dc.subject | Cercopithecus aethiops | |
dc.subject | Dengue | |
dc.subject | Dengue Virus | |
dc.subject | Enzyme-Linked Immunosorbent Assay | |
dc.subject | Humans | |
dc.subject | Immunoglobulin M | |
dc.subject | Neutralization Tests | |
dc.subject | Reproducibility of Results | |
dc.subject | Sensitivity and Specificity | |
dc.subject | Vero Cells | |
dc.subject | Viremia | |
dc.subject | Zika Virus | |
dc.subject | Zika Virus Infection | |
dc.type | Article | |
dc.contributor.department | DUKE-NUS MEDICAL SCHOOL | |
dc.description.doi | 10.1128/JCM.00975-17 | |
dc.description.sourcetitle | Journal of Clinical Microbiology | |
dc.description.volume | 55 | |
dc.description.issue | 10 | |
dc.description.page | 3028-3036 | |
dc.published.state | Published | |
Appears in Collections: | Staff Publications Elements |
Show simple item record
Files in This Item:
File | Description | Size | Format | Access Settings | Version | |
---|---|---|---|---|---|---|
10_1128_JCM_00975-17.pdf | 181.3 kB | Adobe PDF | OPEN | None | View/Download |
This item is licensed under a Creative Commons License